![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0019.jpg)
ü
Rated Voltage : 1.0/1.0kV AC, 1.5kV DC
ü
Max. Permitted Operating Voltage : 1.8kV DC
ü
Temperature Range : - 40 ºC to +120 ºC
ü
Max. Continuous Working Temp : 120º C (20,000h)
ü
Max. Conductor Temperature at Rated Current : 90ºC
ü
Permitted Short Circuit Temperature : 250º C for 5 Sec
ü
AC Test Voltage : 6.5 kV, 50Hz for 5 minutes
ü
Specification : Generally as per EN 50618
ü
Min. Bending Radius : 5 X Cable OD
ü
Conductor Annealed Tinned Flexible
Copper Conductor (APC Optional)
ü
Insulation EBXL - XLPO (Low Smoke
Halogen free)
ü
Core Colour
Red
ü
Inner Sheath Nylon
ü
Outer Sheath
EBXL - XLPO with Anti-Rodent
& Anti-Termite Properties
ü
Sheath Colour
Black with Red stripe
Application
Product Construction
Technical Data
Features
1 X 1.5
1 X 2.5
1 X 4
1 X 6
1 X 10
1 X 16
1 X 25
1 X 35
1 X 50
1 X 70
1 X 95
1 X 120
1 X 150
1 X 185
1 X 240
A518130139
A518160139
A518190139
A518230139
A518270139
A518280139
A518300139
A518320139
A518340139
A518370139
A518380139
A518410139
A518420139
A518440139
A518460139
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
0.51
0.51
0.51
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
www.siechem.comStrand Dia.
(Max.)
Thickness of
Insulation
Thickness of
Outer Sheath
No. of Core x
Nominal Cross
Sectional Area
Part Number
mm
mm
(Nom)
(Nom)
46
58
74
94
135
200
305
405
555
740
965
1190
1480
1850
2350
24
33
44
57
79
107
142
176
221
278
333
390
453
515
620
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
Overall
Diameter
of Cable
(Nom.)
Approx
Cable
Weight
DC Conductor
Resistance
at 20°C
(Max)
0.8
0.8
0.8
0.8
0.8
0.9
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7
5.5
5.9
6.5
7.0
8.0
9.3
11.3
12.6
14.8
16.8
18.8
20.3
22.7
25.2
27.8
mm
mm
kg/km
No. X
Sq.mmSiechem Annealed Tinned Flexible Copper Conductor, EBXL XLPO Insulated, Nylon Inner Sheathed and
EBXL XLPO Outer Sheathed Single Core Solar PV Cable (Anti-Rodent & Anti-Termite Properties)
Ω/km
Catalogue
No.
A518
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
:
:
:
:
:
ü
Used in Photovoltaic Power Supply systems
Indoor & Outdoors
ü
Applicable for Installation in Cable trays,
Conduits and in wall as well as for
direct burial
ü
Resistance against UV, Water, Ozone,
Fluids, Oil, Salt & General Weathering
ü
Electron Beam Cross Linked Halogen free,
Flame Retardant, Low Smoke Emission
Fire Retardant to meet IEC 607541-1/ EN 50268-2
RoHS Compliant as per EU norms.
Voltage Resistance Test complies as per EN 50395
ü
Resistant to Anti-Rodent and Anti-Termite attacks
ü
Current Rating for
Two Loaded Cables
Touching on Surfaces
Amps
Siechem 1C X 4 Sqmm Single Core Nylon Inner Sheathed Solar Cable
Wires & Cables
18
TUV
AS
9100
ISO
45001
ISO
9001
ISO
14001