![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0014.jpg)
13
Nominal Insulation
Thickness
Max. DC Conductor
Resistance at 20°C
Cable Diameter
(Max.)
Cable Weight
(Nom.)
Current Rating for
Two Loaded Cables
Touching on Surfaces
Cross Section
Area
Part Number
Sq.mmmm
mm
Kg/Km
Amps
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
*Note : Insulations colour (XX) - Please add two digits in the part number as per the colour code given hereunder replacing XX while ordering
Red - 01, Black - 04, White - 09
Sheath Colour (YY) please add two digits in the part number as per the colour code given hereunder replacing YY while ordering
Red - 01, Blue - 03, Black - 04, Brown - 08, Grey - 07, Black / Red - 39*
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
2.4
2.6
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.0654
0.0495
5.4
5.9
6.6
7.4
8.8
10.1
12.5
14.0
16.3
18.7
20.8
22.8
25.5
28.5
32.1
32.6
36.8
37
45
58
78
125
175
274
368
511
690
908
1127
1406
1741
2227
2925
3800
24
33
44
57
79
107
142
176
221
278
333
390
453
515
620
714
795
Ω/km
RA47613XXYY
RA47616XXYY
RA47619XXYY
RA47623XXYY
RA47627XXYY
RA47628XXYY
RA47630XXYY
RA47632XXYY
RA47634XXYY
RA47637XXYY
RA47638XXYY
RA47641XXYY
RA47642XXYY
RA47644XXYY
RA47646XXYY
RA47648XXYY
RA47649XXYY
Wires & Cables
Single Core Copper Conductor Electron Beam Cross Linked Solar Cable with Anti-termite & Anti Rodent Resistant
as per EN 50618 Specification
Construction
Features
Conductor
Insulation
Jacket
:
:
:
Annealed Tinned Copper (APC Optional)
according to IEC 60228, Class 5 or as per
customer order
EBXL - XLPO 120°C (Colour White, Red & Black)
Other colours as per customer order
EBXL- XLPO Highly Weather & UV Resistant
(Colour Black, Blue, Red, Brown, Grey,
Black with Red stripe)
Nylon jacket instead of Anti-Temiter & Rodent
Chemicals
Single Core
Siechem Solar Cable Range
Technical data
1.5 to
400sq.mmor its equivalent size in AWG
:
Resistance against UV, Water, Ozone, Fluids, Oil, Salt &
General Weathering.
The environmental protection of cable sheath material;
against to insects bite as well as from the termites and ants
damages in harsh environments .
Anti Termite & anti Rodent properties on sheath.
Expected cable life > 25 years.
Electron Beam Cross Linked
Halogen Free, Flame Retardant, Low Smoke Emission
RoHS compliant as per EU norms
Nominal Sheath
Thickness
0.8
0.8
0.8
0.8
0.8
0.9
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7
2.4
2.6
mm
Siechem EBXL XLPO 120°C Copper EN Specification Solar Cable
TUV
AS
9100
ISO
45001
ISO
9001
ISO
14001
Optional :
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Temperature Range
Max.Temp. at Conductor
Test Voltage
Insulation Resistance Test &
Voltage Test
Rated Voltage
Max. Voltage
Short Circuit Temp
Halogen Free
Flame Retardant
Low Smoke Emission
UV and Weathering Resistance
Flame Reterdant
Resistance against Acid and
Alkaline
Resistance to Fire
Shrinkage Test on Sheath
Dynamic Penetration Test
Expected Life Period
Cold Resistance
Min Bending Radius :
(i) Cable OD x 4 for OD ≤ 8.0 mm
(ii) Cable OD x 5 for 8.0 ≤ OD ≤ 12.0 mm
(iii) Cable OD x 6 for OD >12.0 mm
-40°C to +120°C
120°C (20,000h)
6500V AC for 5 minutes
EN 50395
1.0/1.0kV AC,1.5/1.5 kV DC
1.8 kV DC
+280°C
EN50525-1
EN 60332-1-2
EN 61034-2
EN 50618,EN 50289-4-17
EN60332-1-2
EN 60811-404
Eca approval (from BASEC & TUV)
EN 60811-503
EN 50618
25 years (according EN 60216)
EN 50618, EN 60811-504, EN 60811-505