Table of Contents Table of Contents
Previous Page  18 / 66 Next Page
Information
Show Menu
Previous Page 18 / 66 Next Page
Page Background www.siechem.com

17

Catalogue

No

483

Singlecore Solar Cable Rated 2.3 kV DC

Cable Weight

(Nom.)

Current Rating

Two Cables adjacent

on Surfaces

Cross Section

Area

Part Number

Sq.mm

mm

mm

Kg/Km

Amps

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

*Note : Insulations colour (XX) - Please add two digits in the part number as per the colour code given hereunder replacing XX while ordering

Red - 01, Black - 04, White - 09

Sheath Colour (YY) please add two digits in the part number as per the colour code given hereunder replacing YY while ordering

Red - 01, Blue - 03, Black - 04, Brown - 08, Grey - 07, Black / Red - 39*

5.0

5.5

6.0

7.1

8.4

9.9

12.8

13.9

16.3

18.1

20.8

22.6

24.9

27.7

31.2

33.1

38.8

40

51

67

95

144

213

343

438

612

798

1074

1304

1619

1999

2557

3130

4131

24

33

44

57

79

107

142

176

221

278

333

390

453

515

620

714

795

48313XXYY

48316XXYY

48319XXYY

48323XXYY

48327XXYY

48328XXYY

48330XXYY

48332XXYY

48334XXYY

48337XXYY

48338XXYY

48341XXYY

48342XXYY

48344XXYY

48346XXYY

48348XXYY

48349XXYY

Wires & Cables

Single Core Copper Conductor Electron Beam Cross Linked Solar Cable Rated 2.3 kV Dc as per TUV,

EN & UL Specification

Construction

Features

Conductor

Insulation

Jacket

:

:

:

Annealed Tinned Copper (APC Optional)

according to IEC 60228, Class 5 or as per

customer order

XLPO Highly Weather & UV Resistant

(Colour Black, Black with Red stripe)

XLPO 120°C (Colour White, Red & Black)

Other colours as per customer order

Single Core

Siechem Solar Cable Range

Type of Solar cables

TUV Siechem Single & Multicore Solar Cables meets

specification 2Pfg 1169/08.2007 & EN 50618

UL

Dual

:

:

:

Siechem Single & Multicore Solar Cables meets

UL 4703

Siechem Single & Multicore Solar Cables to meet both

TUV & UL specification

1.5 to

400sq.mm

or its equivalent size in AWG

:

Resistance against UV, Water, Ozone, Fluids, Oil, Salt &

General Weathering.

Electron Beam Cross Linked

Halogen Free, Flame Retardant, Low Smoke Emission

Fire retardant to meet IEC 607541-1/EN 50268-2

RoHS compliant as per EU norms

Max.Temp. at Conductor

Test Voltage

Voltage Resistance Test

Rated Voltage

Short Circuit Temp

: 6500V AC for 5 minutes

:

: 1500 V AC, 2300V DC

+280°C

:

EN 50395

120°C (20,000h)

:

Max. DC Conductor

Resistant at 20°C

Ω/km

13.7

8.21

5.09

3.39

1.95

1.24

0.795

0.565

0.393

0.277

0.210

0.164

0.132

0.108

0.0817

0.0654

0.0495

Nominal

Insulation

Thickness

0.8

0.8

0.8

0.9

1.0

1.2

1.6

1.6

1.8

1.8

2.1

2.1

2.3

2.6

2.9

3.1

3.4

0.6

0.6

0.6

0.7

0.8

0.9

1.2

1.2

1.4

1.4

1.6

1.6

1.8

2.0

2.2

2.4

2.6

Nominal

Sheath

Thickness

mm

Cable Diameter

(Nom.)

Siechem EBXL XLPO 120°C Copper Solar Cable

TUV

AS

9100

ISO

45001

ISO

9001

ISO