Table of Contents Table of Contents
Previous Page  15 / 66 Next Page
Information
Show Menu
Previous Page 15 / 66 Next Page
Page Background www.siechem.com

14

Nominal Insulation

Thickness

Max. DC Conductor

Resistance at 20°C

Cable Diameter

(Max.)

Cable Weight

(Nom.)

Current Rating for

Two Loaded Cables

Touching on Surfaces

Cross Section

Area

Part Number

Sq.mm

mm

mm

Kg/Km

Amps

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

*Note : Insulations colour (XX) - Please add two digits in the part number as per the colour code given hereunder replacing XX while ordering

Red - 01, Black - 04, White - 09

Sheath Colour (YY) please add two digits in the part number as per the colour code given hereunder replacing YY while ordering

Red - 01, Blue - 03, Black - 04, Brown - 08, Grey - 07, Black / Red - 39*

0.7

0.7

0.7

0.7

0.7

0.7

0.9

0.9

1.0

1.1

1.1

1.2

1.4

1.6

1.7

2.4

2.6

13.7

8.21

5.09

3.39

1.95

1.24

0.795

0.565

0.393

0.277

0.210

0.164

0.132

0.108

0.0817

0.0654

0.0495

5.4

5.9

6.6

7.4

8.8

10.1

12.5

14.0

16.3

18.7

20.8

22.8

25.5

28.5

32.1

32.6

36.8

37

45

58

78

125

175

274

368

511

690

908

1127

1406

1741

2227

2925

3800

24

33

44

57

79

107

142

176

221

278

333

390

453

515

620

714

795

Ω/km

B79913XXYY

B79916XXYY

B79919XXYY

B79923XXYY

B79927XXYY

B79928XXYY

B79930XXYY

B79932XXYY

B79934XXYY

B79937XXYY

B79938XXYY

B79941XXYY

B79942XXYY

B79944XXYY

B79946XXYY

B79948XXYY

B79949XXYY

Wires & Cables

Single Core Copper Conductor Electron Beam Cross Linked Solar Cable with Optimized performer in water

as per EN 50618 Specification

Construction

Features

Conductor

Insulation

Jacket

:

:

:

Annealed Tinned Copper (APC Optional)

according to IEC 60228, Class 5 or as per

customer order

EBXL- XLPO Highly Weather & UV Resistant

(Colour Black, Blue, Red, Brown, Grey,

Black with Red stripe)

EBXL - XLPO 120°C (Colour White, Red & Black)

Other colours as per customer order

Single Core

Siechem Solar Cable Range

1.5 to

400sq.mm

or its equivalent size in AWG

:

Resistance against UV, Water, Ozone, Fluids, Oil, Salt &

General Weathering.

High volume resistance even after long term period in water.

Permanent water contact AD8 acc. IEC 60364-5-51,

1 mtr. in max. submersion depth at temperature of

widely unmoved water between 5°C and 40°C

Water Resistant AD 8 to meet as per IEC 60364-5-51

& IEC 60529

Electron Beam Cross Linked

Halogen Free, Flame Retardant, Low Smoke Emission

Nominal Sheath

Thickness

0.8

0.8

0.8

0.8

0.8

0.9

1.0

1.1

1.2

1.2

1.3

1.3

1.4

1.6

1.7

2.4

2.6

mm

Technical data

RoHS compliant as per EU norms

Expected cable life > 25 years.

Temperature Range

Max.Temp. at Conductor

Test Voltage

Insulation Resistance Test &

Voltage Test

Rated Voltage

Max. Voltage

Short Circuit Temp

Halogen Free

Flame Retardant

Low Smoke Emission

UV and Weathering Resistance

Flame Reterdant

Resistance against Acid and

Alkaline

Resistance to Fire

Shrinkage Test on Sheath

Dynamic Penetration Test

Expected Life Period

Cold Resistance

Min Bending Radius :

(i) Cable OD x 4 for OD ≤ 8.0 mm

(ii) Cable OD x 5 for 8.0 ≤ OD ≤ 12.0 mm

(iii) Cable OD x 6 for OD >12.0 mm

-40°C to +120°C

120°C (20,000h)

6500V AC for 5 minutes

EN 50395

1.0/1.0kV AC,1.5/1.5 kV DC

1.8 kV DC

+280°C

EN50525-1

EN 60332-1-2

EN 61034-2

EN 50618,EN 50289-4-17

EN60332-1-2

EN 60811-404

Eca approval (from BASEC & TUV)

EN 60811-503

EN 50618

25 years (according EN 60216)

EN 50618, EN 60811-504, EN 60811-505

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

Siechem EBXL XLPO 120°C Copper EN Specification Solar Cable

TUV

AS

9100

ISO

45001

ISO

9001

ISO

14001