15
Catalogue
No
RA476
Singlecore Solar Cable
Nominal Insulation
Thickness
Max. DC Conductor
Resistance at 20°C
Cable Diameter
(Max.)
Cable Weight
(Nom.)
Current Rating for
Two Loaded Cables
Touching on Surfaces
Cross Section
Area
Part Number
Sq.mmmm
mm
Kg/Km
Amps
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
*Note : Insulations colour (XX) - Please add two digits in the part number as per the colour code given hereunder replacing XX while ordering
Red - 01, Black - 04, White - 09
Sheath Colour (YY) please add two digits in the part number as per the colour code given hereunder replacing YY while ordering
Red - 01, Blue - 03, Black - 04, Brown - 08, Grey - 07, Black / Red - 39*
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
2.4
2.6
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.0654
0.0495
5.4
5.9
6.6
7.4
8.8
10.1
12.5
14.0
16.3
18.7
20.8
22.8
25.5
28.5
32.1
32.6
36.8
37
45
58
78
125
175
274
368
511
690
908
1127
1406
1741
2227
2925
3800
24
33
44
57
79
107
142
176
221
278
333
390
453
515
620
714
795
Ω/km
A47613XXYY
A47616XXYY
A47619XXYY
A47623XXYY
A47627XXYY
A47628XXYY
A47630XXYY
A47632XXYY
A47634XXYY
A47637XXYY
A47638XXYY
A47641XXYY
A47642XXYY
A47644XXYY
A47646XXYY
A47648XXYY
A47649XXYY
Wires & Cables
Single Core Copper Conductor Electron Beam Cross Linked Solar Cable as per EN 50618 Specification
Construction
Features
Conductor
Insulation
Jacket
:
:
:
Annealed Tinned Copper (APC Optional)
according to IEC 60228, Class 5 or as per
customer order
EBXL- XLPO Highly Weather & UV Resistant
(Colour Black, Blue, Red, Brown, Grey,
Black with Red stripe)
EBXL - XLPO 120°C (Colour White, Red & Black)
Other colours as per customer order
Resistance against UV, Water, Ozone, Fluids, Oil,
Salt & General Weathering.
Electron Beam Cross Linked
Halogen Free
Flame Retardant
Low Smoke Emission
RoHS compliant as per EU norms
Nominal Sheath
Thickness
0.8
0.8
0.8
0.8
0.8
0.9
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7
2.4
2.6
mm
Siechem EBXL XLPO 120°C Copper EN Specification Solar Cable
Technical data
:
:
:
:
:
:
:
:
:
:
:
:
Temperature Range
Max.Temp. at Conductor
Test Voltage
Insulation Resistance Test &
Voltage Test
Rated Voltage
Max. Voltage
Short Circuit Temp
Halogen Free
Flame Retardant
Low Smoke Emission
UV and Weathering Resistance
Flame Reterdant
Min Binding Radius :
(i) Cable OD x 4 for OD ≤ 0./8 mm
(ii) Cable OD x 5 for 8.0 ≤ OD ≤ 12.0 mm
(iii) Cable OD x 6 for OD >12.0 mm
-40°C to +120°C
120°C (20,000h)
6500V AC for 5 minutes
EN 50395
1.0/1.0kV AC,1.5/1.5 kV DC
1.8 kV DC
+280°C
EN50525-1
EN 60332-1-2
EN 61034-2
EN 50618,EN 50289-4-17
EN60332-1-2
TUV
AS
9100
ISO
45001
ISO
9001
ISO
14001