Rated Voltage : 1/1 kV AC (1.5/1.5 kV DC Nom)

ü

Max. Permitted Operating Voltage : 1.8kV DC

ü

Temperature Range : -40 ºC to +120 ºC

ü

Current Carrying Capacity :

(i) In Ground at 30ºC : 47 A

(ii) In Duct at 30ºC : 41A

(iii) In air at 60ºC : 44A

(iv) Two cables adjacent on surface : 44A

ü

Short Circuit Capacity for 1 sec : 0.552 kA

ü

Current Carrying Capacity :

(i) Max. Conductor temperature at rated current : 90ºC

(ii) Ambient Air Temperature : 45ºC

(iii) Ambient Soil temperature : 30ºC

(iv) Over load capacity : 130ºC

ü

Max. Continuous working temp : 120º C

ü

Max. Conductor temperature at rated current : 90ºC

ü

Max. Conductor temp at of Terminator short circuit

for 5 Sec : 250º C

ü

AC Test Voltage : 6.5 kV,50Hz,5min

ü

DC Test Voltage : 15 kV for 5min

ü

Approx Dielectric Strength : 20 kV/ mm

ü

Specification : Generally As per EN 50618

ü

Min. Binding Radius : 5 X Cable OD

ü

Conductor Annealed Tinned Flexible

Copper Conductor

ü

Insulation EBXL - XLPO -Low Smoke

Halogen free\

ü

Core Color Black

ü

Inner sheath Nylon

ü

Outer Sheath EBXL - XLPO -120ºC

ü

Sheath Colour Black With Red Strip

Application

Product Construction

Technical Data

Features

2 X 4

A7891902

0.7

2.5

56/0.31

www.siechem.com

Conductor

Diameter

(Nom)

No. of Strands /

Strand Dia.

(Max.)

Thickness of

Insulation

Thickness of

Outer Sheath

No. of Cores x

Nominal Cross

Sectional Area

Part number

mm

Nos/mm

mm

Nom

Nom

Min

Min

140

5.09

Overall

Diameter

of Cable

(Nom.)

Approx

Cable

Weight

DC Conductor

Resistance

20°C

(Max)

(6.6 x 13.6) ± 0.6

0.8 0.58

0.53

mm mm

mm

mm

kg/km

Sq.mm

Siechem Annealed Tinned Flexible Copper Conductor, EBXL XLPO Insulated, Nylon Inner Sheathed & EBXL XLPO Outer Sheathed

(Twin Parallel) Solar PV Cable.

Ω/km

Catalogue

No.

A789

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

:

:

:

:

:

:

ü

Used in Photovoltaic Power Supply systems

Indoor & Out doors

ü

Applicable for Installation in Cable trays,

Conduits, on and in wall as well as for

direct burial

ü

Resistance against UV, Water. Ozone,

Fluids, Oil, Salt & General Weathering

ü

Electron Beam Cross Linked Halogen free,

Flame Retardant, Low Smoke Emission

Fire retardant to meet IEC 607541-1/ EN 50268-2

RoHS Compliant as per EU norms

Resistant to Anti-Rodent and Anti-Termite attacks

ü

Wires & Cables

Siechem 2C X 4 Sqmm Twin Parallel Solar Cable

22

TUV

AS

9100

ISO

45001

ISO

9001

ISO

14001