43

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Wires & Cables

Product Construction

Technical Data

ü

Conductor : Annealed Plain Copper Conductor

according to ISO 19642 (Stranded)

ü

Insulation : Electron Beam Cross linked

Polyolefin

Class D (Thin Wall)

ü

Insulation

Colour

: Orange (or) As Per

Customer Request

Siechem

Single Core, Stranded Class D (Thin) 1000V AC EV 150 Cable

2D View

Nominal

Cross-

Section

No. of

Strands

Stand dia.

(Max)

Conductor Construction

Over all Diameter

Weight

Approx.

Insulation

Thickness

2

mm

nos.

kg/km

mm

Part

Number

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

(Min.)

mm

mm

Current

Carrying

Capacity

Amps

mm

54.4

37.1

24.7

18.5

14.9

12.7

9.42

7.60

6.15

4.71

3.94

3.14

2.38

1.82

1.52

1.16

0.955

0.743

0.647

0.527

0.473

0.368

0.315

0.259

0.219

0.196

Min.

Max.

1C x 0.35

1C x 0.5

1C x 0.75

1C x 1

1C x 1.25

1C x 1.5

1C x 2

1C x 2.5

1C x 3

1C x 4

1C x 5

1C x 6

1C x 8

1C x 10

1C x 12

1C x 16

1C x 20

1C x 25

1C x 30

1C x 35

1C x 40

1C x 50

1C x 60

1C x 70

1C x 85

1C x 95

0.20

0.22

0.24

0.24

0.24

0.24

0.28

0.28

0.32

0.32

0.32

0.32

0.32

0.48

0.48

0.52

0.52

0.52

0.64

0.64

0.71

0.71

0.80

0.80

0.90

0.90

1.20

1.40

1.70

1.90

2.10

2.20

2.50

2.70

3.10

3.40

3.90

4.00

4.60

5.30

5.80

6.40

7.00

7.90

8.70

9.40

10.00

11.00

12.00

13.00

14.40

15.30

1.40

1.60

1.90

2.10

2.30

2.40

2.80

3.00

3.40

3.70

4.20

4.30

5.00

6.00

6.50

7.20

7.80

8.70

9.60

10.40

11.10

12.20

13.30

14.40

15.80

16.70

0

0

ü

Rated Temperature : - 40 C to +150 C (3000 Hours)

2

ü

Max. Rated Voltage : (i) 600V AC / 900V DC (0.35mm )

(ii) 1000V AC / 1500V DC

2

(0.5mm and above)

ü

(ISO Conductor size

0.35Sq.mm

shall not be used for

1000V AC / 1500V DC Cables)

ü

Test Voltage :

(i) 3kV AC for 5 mins (0.35 Sqmm)

(ii) 10kV AC for 5 mins (≥ 0.5 Sqmm)

ü

Insulation Faults : 6kV AC for 900V & 8kV AC for 1500V DC

ü

Specification : ISO 19642-5, ISO 6722, Generally

as per QC / T 1037-2016**

A94305XX

A94306XX

A94308XX

A94310XX

A94312XX

A94313XX

A94314XX

A94316XX

A94317XX

A94319XX

A94321XX

A94323XX

A94325XX

A94327XX

A943A11XX

A94328XX

A94356XX

A94330XX

A94357XX

A94332XX

A94358XX

A94334XX

A94335XX

A94337XX

A94359XX

A94338XX

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

o

o

ü

Current Carrying capacity given is for the maximum conductor operating of 150 C and

ambient

air temperature of 40 C.

ü

** Conductor construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/ T1037-2016 or any specific construction, the same can also be supplied.

13

16

22

26

30

33

41

46

54

64

72

82

100

119

135

160

180

211

230

259

278

321

354

396

437

469

A943

Catalogue

No

7

19

19

19

19

19

19

37

44

56

70

84

116

144

174

228

276

355

408

501

558

717

838

1019

1197

1347

5

6

9

11

14

16.5

22.5

26

33

41

51

60

81

104

124

162

195

245

285

350

390

495

575

695

820

920

0.26

0.19

0.24

0.27

0.30

0.33

0.38

0.30

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

0.31

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949

Application

Features

ü

Electrical vehicle charging station

ü

Portable cables for hybrid & electric vehicles

ü

Designed to be installed (both indoors

and outdoors) at private homes, communal

blocks, companies & other places

ü

Enchanced DV power rating makes it ideal

for high powered charging stations

ü

Designed to be installed in public access

environment likes urban spaces, shopping

centre, car park, airport etc.

ü

Suitability for installation with possibility of

water immersion

ü

Designed for harsh mechanical environments.

ü

Chemical and abrasion resistant.

ü

Hydrolyse resistant.

ü

Thermal stress resistant.

ü

Halogen free.

ü

Flame resistant.

ü

High flexibility and easy to use.

ü

Light weight, thin diameter.

ü

Cable is constructed to prevent injury and leakage.

ü

Low corrosive gas emission.