43
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Wires & Cables
Product Construction
Technical Data
ü
Conductor : Annealed Plain Copper Conductor
according to ISO 19642 (Stranded)
ü
Insulation : Electron Beam Cross linked
Polyolefin
Class D (Thin Wall)
ü
Insulation
Colour
: Orange (or) As Per
Customer Request
Siechem
Single Core, Stranded Class D (Thin) 1000V AC EV 150 Cable
2D View
Nominal
Cross-
Section
No. of
Strands
Stand dia.
(Max)
Conductor Construction
Over all Diameter
Weight
Approx.
Insulation
Thickness
2
mm
nos.
kg/km
mm
Part
Number
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
(Min.)
mm
mm
Current
Carrying
Capacity
Amps
mm
54.4
37.1
24.7
18.5
14.9
12.7
9.42
7.60
6.15
4.71
3.94
3.14
2.38
1.82
1.52
1.16
0.955
0.743
0.647
0.527
0.473
0.368
0.315
0.259
0.219
0.196
Min.
Max.
1C x 0.35
1C x 0.5
1C x 0.75
1C x 1
1C x 1.25
1C x 1.5
1C x 2
1C x 2.5
1C x 3
1C x 4
1C x 5
1C x 6
1C x 8
1C x 10
1C x 12
1C x 16
1C x 20
1C x 25
1C x 30
1C x 35
1C x 40
1C x 50
1C x 60
1C x 70
1C x 85
1C x 95
0.20
0.22
0.24
0.24
0.24
0.24
0.28
0.28
0.32
0.32
0.32
0.32
0.32
0.48
0.48
0.52
0.52
0.52
0.64
0.64
0.71
0.71
0.80
0.80
0.90
0.90
1.20
1.40
1.70
1.90
2.10
2.20
2.50
2.70
3.10
3.40
3.90
4.00
4.60
5.30
5.80
6.40
7.00
7.90
8.70
9.40
10.00
11.00
12.00
13.00
14.40
15.30
1.40
1.60
1.90
2.10
2.30
2.40
2.80
3.00
3.40
3.70
4.20
4.30
5.00
6.00
6.50
7.20
7.80
8.70
9.60
10.40
11.10
12.20
13.30
14.40
15.80
16.70
0
0
ü
Rated Temperature : - 40 C to +150 C (3000 Hours)
2
ü
Max. Rated Voltage : (i) 600V AC / 900V DC (0.35mm )
(ii) 1000V AC / 1500V DC
2
(0.5mm and above)
ü
(ISO Conductor size
0.35Sq.mmshall not be used for
1000V AC / 1500V DC Cables)
ü
Test Voltage :
(i) 3kV AC for 5 mins (0.35 Sqmm)
(ii) 10kV AC for 5 mins (≥ 0.5 Sqmm)
ü
Insulation Faults : 6kV AC for 900V & 8kV AC for 1500V DC
ü
Specification : ISO 19642-5, ISO 6722, Generally
as per QC / T 1037-2016**
A94305XX
A94306XX
A94308XX
A94310XX
A94312XX
A94313XX
A94314XX
A94316XX
A94317XX
A94319XX
A94321XX
A94323XX
A94325XX
A94327XX
A943A11XX
A94328XX
A94356XX
A94330XX
A94357XX
A94332XX
A94358XX
A94334XX
A94335XX
A94337XX
A94359XX
A94338XX
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
o
o
ü
Current Carrying capacity given is for the maximum conductor operating of 150 C and
ambient
air temperature of 40 C.
ü
** Conductor construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/ T1037-2016 or any specific construction, the same can also be supplied.
13
16
22
26
30
33
41
46
54
64
72
82
100
119
135
160
180
211
230
259
278
321
354
396
437
469
A943
Catalogue
No
7
19
19
19
19
19
19
37
44
56
70
84
116
144
174
228
276
355
408
501
558
717
838
1019
1197
1347
5
6
9
11
14
16.5
22.5
26
33
41
51
60
81
104
124
162
195
245
285
350
390
495
575
695
820
920
0.26
0.19
0.24
0.27
0.30
0.33
0.38
0.30
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949
Application
Features
ü
Electrical vehicle charging station
ü
Portable cables for hybrid & electric vehicles
ü
Designed to be installed (both indoors
and outdoors) at private homes, communal
blocks, companies & other places
ü
Enchanced DV power rating makes it ideal
for high powered charging stations
ü
Designed to be installed in public access
environment likes urban spaces, shopping
centre, car park, airport etc.
ü
Suitability for installation with possibility of
water immersion
ü
Designed for harsh mechanical environments.
ü
Chemical and abrasion resistant.
ü
Hydrolyse resistant.
ü
Thermal stress resistant.
ü
Halogen free.
ü
Flame resistant.
ü
High flexibility and easy to use.
ü
Light weight, thin diameter.
ü
Cable is constructed to prevent injury and leakage.
ü