Table of Contents Table of Contents
Previous Page  59 / 162 Next Page
Information
Show Menu
Previous Page 59 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

2D View

Siechem

SXKB RoHS

ü

Temperature Range :

0

0

- 40 C to +90 C (3000 Hours)

ü

Standard : Volvo type

ü

Rated Voltage : 750 V

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Nominal

Thickness

of sheath

Cable

Overall

Diameter

Weight

Approx.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

mm

Amps

Features

ü

Intended for use as battery cable. PPL.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Flexible conductors with Electron Beam Cross

Linked Polyolefin thin wall insulation for smaller

diameter and lesser weight.

ü

Excellent flexibility.

ü

Heat resistant.

ü

Insulation : Flame retardant, halogen-free

Cross-linked polyethylene (XLPE)

ü

Sheath : Special lead free PVC Compound

type TI 3 according to EN 50363-3 (HD 21.1.S4)

ü

Colour : Black.

ü

Single core

Wires & Cables

Note : XX* YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX YY while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 100 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

ü

Conductor : Plain annealed copper Wires

Flexible Class 5 according to IEC 60228

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

864

86427XXYY

86428XXYY

86430XXYY

86432XXYY

86434XXYY

86437XXYY

86438XXYY

58

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

10

16

25

35

50

70

95

74

118

183

259

382

323

421

0.41

0.41

0.41

0.41

0.41

0.51

0.51

0.8

0.8

0.8

0.8

1.0

1.6

1.6

0.7

0.7

0.7

0.7

0.8

0.8

0.9

7.3

8.3

9.7

10.9

13.0

15.4

17.8

mm

121

180

280

360

510

750

950

1.78

1.21

0.78

0.554

0.386

0.272

0.206

60

76

96

120

155

195

240

500

500

500

500

500

500

500

SXKB

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949