![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0064.jpg)
Application
Product Construction
Technical Data
Wires & Cables
2D View
Siechem
Auto 85 TW Class A RoHS
0
0
ü
Temperature Range: -40 C to +85 C
(3000 Hours)
ü
Standard : ISO 6722 Class A (Thin wall)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
Auto 85 TW
Features
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Unliya conductor stranding
ü
Reduced diameter wall thickness
ü
Saving of insulation material, resulting in
substantial weight reduction
ü
Conductor : Soft / annealed Plain Copper
according to ISO 6722 (Symmetrical)
ü
Insulation : PVC with properties according
to ISO 6722 class A, Lead free(thin wall)
ü
Colour : As per customer order
ü
Cable construction according to ISO 6722,
Class A
ü
Single core, Single layer insulation
Wires & Cables
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
max.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
mm
mm
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
o
o
ü
Current Carrying capacity given is for the maximum conductor operating of 85 C and ambient air temperature of 40 C.
ü
Cables are also available in dual colored insulation
ü
* Other length as per Customer order.
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
A823
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
0.35
0.50
0.75
1
1.5
2
2.5
3
4
5
6
10
16
25
0.25
0.28
0.30
0.30
0.30
0.35
0.35
0.40
0.40
0.40
0.40
0.60
0.65
0.65
1.30
1.60
1.90
2.10
2.40
2.80
3.00
3.40
3.70
4.20
4.30
6.00
7.90
9.40
54.4
37.1
24.7
18.5
12.7
9.42
7.60
6.15
4.71
3.94
3.14
1.82
1.16
0.743
2000
2000
2000
2000
2000
2000
2000
1000
1000
1000
1000
1000
1000
1000
7
19
19
19
19
19
37
37
37
37
37
63
105
154
0.27
0.19
0.24
0.27
0.33
0.38
0.28
0.34
0.38
0.43
0.45
0.46
0.46
0.46
5
6
9
11
16
23
26
34
42
53
60
106
176
249
0.90
1.10
1.30
1.50
1.80
2.00
2.20
2.40
2.80
3.10
3.40
4.50
6.30
7.80
Class
A B C D E F G H
o
o
o
o
o
o
o
o
+85 C +100 C +125 C +150 C +175 C +200 C +225 C +250 C
Temperature
o
from -40 C to
Cables confirming to the below categories are also available according to customer requirement
Conductor Configuration : Symmetrical, Asymmetrical, Flexible
Insulation thickness : Standard, Thin wall & Ultra thin wall
ISO 6722 Temperature Class Rating :
A82305XX
A82306XX
A82308XX
A82310XX
A82313XX
A82314XX
A82316XX
A82317XX
A82319XX
A82321XX
A82323XX
A82327XX
A82328XX
A82330XX
63
Current
Carrying
Capacity
Amps
9
11
15
18
23
28
32
37
44
50
57
83
112
148
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949