![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0058.jpg)
Application
Product Construction
Technical Data
Wires & Cables
2D View
Siechem
RK RoHS
ü
Temperature Range :
0
0
- 40 C to +70 C (3000 Hours)
ü
Standard : Volvo type
ü
Rated voltage, cable of one colour
2
300 V at rated area ≤ 1mm
2
450 V at rated area 1.5 -16mm
2
750 V at rated area ≥ 25 mm
Rated voltage : two-coloured: 100V
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
Current
Carrying
Capacity
mm
Amps
RK
Features
ü
Low-tension electric wire harness cable for automobiles.
ü
Used in motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Especially used circuits requiring heat resistance
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Extra flexibility.
ü
Heat resistant
ü
Insulation : PVC Class TI 1
ü
Colour : As per customer order.
ü
Single core
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature 70 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
ü
Conductor : Extra multi stranded bare copper
conductor construction according to volvo
1052501
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
868
86805XX
86806XX
86808XX
86810XX
86813XX
86816XX
86819XX
86823XX
86827XX
86828XX
86830XX
86832XX
86834XX
86837XX
86838XX
86841XX
57
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
0.38
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
12
16
24
32
30
50
56
84
80
126
196
276
396
360
475
608
0.21
0.21
0.21
0.21
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
0.3
0.6
0.6
0.6
0.7
0.8
0.8
0.8
1.0
1.0
1.1
1.2
1.4
1.4
1.6
1.6
1.5
2.6
2.8
3.0
3.5
4.2
4.8
6.3
7.6
8.8
10.8
12.8
14.5
16.6
19
21
6
9
11
13
19
31
47
72
115
168
203
357
508
750
1000
1300
54.4
39.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
5
8
10
12
16
22
30
38
52
76
96
120
155
195
240
280
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949