WXC RoHS
ü
Temperature Range :
0
0
- 40 C to +125 C (3000 Hours)
ü
Standard : SAE J1678
ü
WXC : Ultra thin wall XLPE Insulation
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
mm
mm
WXC
Features
ü
Low voltage cable is designed for used at nominal
voltage of 60 V DC (60 V AC rms ) or surface vehicles
electrical systems.
ü
Flame retardant
ü
Excellent heat resistance
ü
Flexible
ü
Insulation : XLPE, Ultra- thin wall
flame -retardant, halogen- free
material acc. to SAE J 1678 / Ford WSS
MIL -135-A / Lear UTMS 12501
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
ü
Conductor : Soft-annealed electrolytic copper
E- Cu ETP1 according to ASTM B3 bare conductor
construction according to customer specification
SAE J 1127
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
A883
A88383XX
A88382XX
A88381XX
A88380XX
A88379XX
A88378XX
56
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
4
7
8
12
19
30
53.9
34.3
23.0
15.5
9.44
6.0
500
500
500
500
500
500
1.35
1.55
1.75
2.03
2.39
3.00
0.20
0.20
0.20
0.20
0.20
0.24
0.76
0.97
1.17
1.45
1.8
2.3
0.25
0.32
0.23
0.28
0.36
0.45
7
7
19
19
19
19
0.35
0.5
0.8
1.3
2
3
Size
AWG
22
20
18
16
14
12
Current
carrying
capacity
Amps
12
16
21
27
37
51
OHSAS