Table of Contents Table of Contents
Previous Page  56 / 162 Next Page
Information
Show Menu
Previous Page 56 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

2D View

Siechem

WTA RoHS

ü

Temperature Range :

- 40°C to +85°C (3000 Hours)

ü

Standard : SAE J1678

ü

WTA : Ultra Thin wall PVC Insulation

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm

mtrs

kg/km

mm

Standard

Length*

Part

Number

mm

mm

WTA

Features

ü

Low-voltage Cable is desingned for used at nominal

Voltage of 60 V DC (60 V AC rms) or surface vehicles

electrical systems

ü

Flexible

ü

Excellent resistance to oil and flame

ü

Insulation : PVC Ultra - Thin wall

accoriding to SAE J 1678 Ford WSBM1 L134 -A /

Chrysler MS 9532 / Lear UTMS 12501

Wires & Cables

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 85 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

ü

Conductor : Soft-annealed electrolytic copper

E- Cu ETP1 according to ASTM B3 conductor construction

according to customer specifications

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

A882

A88283XX

A88282XX

A88281XX

A88280XX

A88279XX

A88278XX

55

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

4

7

8

12

19

30

53.9

34.3

23.0

15.5

9.44

6.0

500

500

500

500

500

500

1.35

1.55

1.75

2.03

2.39

3.00

0.20

0.20

0.20

0.20

0.20

0.24

0.76

0.97

1.17

1.45

1.8

2.3

0.25

0.32

0.23

0.28

0.36

0.45

7

7

19

19

19

19

0.35

0.5

0.8

1.3

2

3

Size

AWG

22

20

18

16

14

12

Current

Carrying

Capacity

Amps

9

12

15

20

27

37

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949