Table of Contents Table of Contents
Previous Page  62 / 162 Next Page
Information
Show Menu
Previous Page 62 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

2D View

Siechem

R4 RoHS

ü

Temperature Range :

0

0

- 40 C to +150 C (3000 Hours)

ü

Standard : Volvo 1059032

ü

Rated Voltage :50 VDC

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Min.

2

mm

nos.

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

Amps

Features

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Flexible conductors with Electron Beam Cross

Linked Polyolefin thin wall insulation for smaller

diameter and lesser weight.

ü

Excellent flexibility.

ü

Heat resistant.

ü

Insulation : Class 4, Equivalent to ISO 6722

Temperature Class D

ü

Colour : As per customer order

ü

Single core

Wires & Cables

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 150 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

ü

Conductor : Extra multi stranded bare copper

comductor ,comstraction according to volvo 1059032

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

866

86605XX

86606XX

86608XX

86610XX

86613XX

86616XX

86619XX

86623XX

61

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

0.35

0.5

0.75

1

1.5

2.5

4

6

7

19

19

32

37

37

56

84

0.26

0.19

0.23

0.20

0.22

0.28

0.31

0.31

0.20

0.22

0.24

0.24

0.24

0.28

0.32

0.32

1.4

1.6

1.9

2.1

2.4

3.0

3.7

4.30

mm

4.5

6.0

9.4

12

16

25

47

69

54.4

37.1

24.7

18.5

12.7

7.6

4.71

3.14

5

8

10

12

16

22

30

38

500

500

500

500

500

500

500

500

ü

Manufacturing specifications STD 7611,131.

R4

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF