Table of Contents Table of Contents
Previous Page  125 / 162 Next Page
Information
Show Menu
Previous Page 125 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

CABT 0.75

Sq.mm

T3

Siechem

CABT (T3)

Features

ü

Low-tension electric wire for automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Heat resistance

ü

Halogen free

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

Y811

0

0

ü

Temperature Range : -40 C to + 125 C

ü

System Voltage (Nom.) : ≤ 60V DC (or) 25V AC

ü

Specification : MS 90034 & ISO 6722-1

C - Temperature Class C

A - Symmetrical

B - Bare Copper

T - Thin Wall

ü

Conductor : Soft-annealed electrolytic bare

Copper according to ISO 6722

ü

Cable construction according to

ISO 6722 Class C (Thin wall)

ü

Insulation : Electron Beam Cross Linked

Polyolefin 125°C

ü

Colour : As per customer order.

ü

Single core, Single layer insulation

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Cable

Overall

Diameter

Weight

Approx.

(Min/Max)

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

mm

Amps

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

Y81105XX

Y81106XX

Y81108XX

Y81110XX

Y81113XX

Y81114XX

Y81116XX

Y81117XX

Y81119XX

Y81121XX

Y81123XX

Y81125XX

Y81127XX

Y811A11XX

Y81128XX

Y81156XX

Y81130XX

54.4

37.1

24.7

18.5

12.7

9.42

7.60

6.15

4.71

3.94

3.14

2.38

1.82

1.52

1.16

0.995

0.743

12

15

20

24

30

37

42

49

58

66

75

91

108

123

144

161

189

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

7

7

19

19

19

19

37

37

37

37

37

98

63

154

105

247

154

0.27

0.32

0.24

0.27

0.33

0.38

0.28

0.34

0.38

0.43

0.45

0.33

0.46

0.33

0.46

0.33

0.46

5

7

10

11

17

23

25

35

43

54

59

82

105

135

167

208

245

0.9

1.1

1.3

1.5

1.8

2.0

2.2

2.4

2.8

3.1

3.4

4.3

4.5

5.4

5.8

6.9

7.2

0.35

0.5

0.75

1

1.5

2

2.5

3

4

5

6

8

10

12

16

20

25

0.25

0.28

0.30

0.30

0.30

0.35

0.35

0.40

0.40

0.40

0.40

0.40

0.60

0.60

0.65

0.65

0.65

1.20/1.40

1.40/1.60

1.70/1.90

1.90/2.10

2.20/2.40

2.50/2.80

2.70/3.00

3.10/3.40

3.40/3.70

3.90/4.20

4.00/4.30

4.60/5.00

5.30/6.00

5.80/6.50

6.40/7.20

7.00/7.80

7.90/8.70

124

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949