![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0125.jpg)
Application
Product Construction
Technical Data
Wires & Cables
CABT 0.75
Sq.mmT3
Siechem
CABT (T3)
Features
ü
Low-tension electric wire for automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Heat resistance
ü
Halogen free
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
Y811
0
0
ü
Temperature Range : -40 C to + 125 C
ü
System Voltage (Nom.) : ≤ 60V DC (or) 25V AC
ü
Specification : MS 90034 & ISO 6722-1
C - Temperature Class C
A - Symmetrical
B - Bare Copper
T - Thin Wall
ü
Conductor : Soft-annealed electrolytic bare
Copper according to ISO 6722
ü
Cable construction according to
ISO 6722 Class C (Thin wall)
ü
Insulation : Electron Beam Cross Linked
Polyolefin 125°C
ü
Colour : As per customer order.
ü
Single core, Single layer insulation
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
(Min/Max)
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
Current
Carrying
Capacity
mm
mm
Amps
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
Y81105XX
Y81106XX
Y81108XX
Y81110XX
Y81113XX
Y81114XX
Y81116XX
Y81117XX
Y81119XX
Y81121XX
Y81123XX
Y81125XX
Y81127XX
Y811A11XX
Y81128XX
Y81156XX
Y81130XX
54.4
37.1
24.7
18.5
12.7
9.42
7.60
6.15
4.71
3.94
3.14
2.38
1.82
1.52
1.16
0.995
0.743
12
15
20
24
30
37
42
49
58
66
75
91
108
123
144
161
189
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
7
7
19
19
19
19
37
37
37
37
37
98
63
154
105
247
154
0.27
0.32
0.24
0.27
0.33
0.38
0.28
0.34
0.38
0.43
0.45
0.33
0.46
0.33
0.46
0.33
0.46
5
7
10
11
17
23
25
35
43
54
59
82
105
135
167
208
245
0.9
1.1
1.3
1.5
1.8
2.0
2.2
2.4
2.8
3.1
3.4
4.3
4.5
5.4
5.8
6.9
7.2
0.35
0.5
0.75
1
1.5
2
2.5
3
4
5
6
8
10
12
16
20
25
0.25
0.28
0.30
0.30
0.30
0.35
0.35
0.40
0.40
0.40
0.40
0.40
0.60
0.60
0.65
0.65
0.65
1.20/1.40
1.40/1.60
1.70/1.90
1.90/2.10
2.20/2.40
2.50/2.80
2.70/3.00
3.10/3.40
3.40/3.70
3.90/4.20
4.00/4.30
4.60/5.00
5.30/6.00
5.80/6.50
6.40/7.20
7.00/7.80
7.90/8.70
124
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949