Page Background

Application

Product Construction

Technical Data

Wires & Cables

CCBT 0.75

Sq.mm

T3

Siechem

CCBT (T3)

Features

ü

Low-tension electric wire for automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Heat resistance

ü

Halogen free

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

Y805

0

0

ü

Temperature Range : -40 C to + 125 C

ü

Specification : MS 90034 & ISO 6722-1

C - Temperature Class C

C - Flexible

B - Bare Copper

T - Thin Wall

ü

Conductor : Soft-annealed electrolytic bare

Copper according to ISO 6722

ü

Cable construction according to

ISO 6722 Class C (Thin wall)

ü

Insulation : Electron Beam Cross Linked

Polyolefin 125°C

ü

Colour : As per customer order.

ü

Single core, Single layer insulation

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Cable

Overall

Diameter

Weight

Approx.

(Min/Max)

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

mm

Amps

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

Y80505XX

Y80506XX

Y80508XX

Y80510XX

Y80513XX

Y80514XX

Y80516XX

Y80517XX

Y80519XX

Y80521XX

Y80523XX

Y80525XX

Y80527XX

Y805A11XX

Y80528XX

Y80556XX

Y80530XX

54.4

37.1

24.7

18.5

12.7

9.42

7.60

6.15

4.71

3.94

3.14

2.38

1.82

1.52

1.16

0.995

0.743

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

19

19

38

54

76

105

140

160

224

250

320

240

320

380

512

610

790

0.16

0.19

0.16

0.16

0.16

0.16

0.16

0.16

0.16

0.16

0.16

0.21

0.21

0.21

0.21

0.21

0.21

0.9

1.1

1.3

1.5

1.8

2.0

2.2

2.4

2.8

3.1

3.4

4.3

4.5

5.4

5.8

6.9

7.2

0.35

0.5

0.75

1

1.5

2

2.5

3

4

5

6

8

10

12

16

20

25

0.25

0.28

0.30

0.30

0.30

0.35

0.35

0.40

0.40

0.40

0.40

0.40

0.60

0.60

0.65

0.65

0.65

1.20/1.40

1.40/1.60

1.70/1.90

1.90/2.10

2.20/2.40

2.50/2.80

2.70/3.00

3.10/3.40

3.40/3.70

3.90/4.20

4.00/4.30

4.60/5.00

5.30/6.00

5.80/6.50

6.40/7.20

7.00/7.80

7.90/8.70

5

7

10

11

17

23

25

35

43

54

59

82

105

135

167

208

245

12

15

20

24

30

37

42

49

58

66

75

91

108

123

144

161

189

128

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949