Table of Contents Table of Contents
Previous Page  131 / 162 Next Page
Information
Show Menu
Previous Page 131 / 162 Next Page
Page Background

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

B895

130

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Application

Product Construction

Technical Data

Features

Wires & Cables

ü

Temperature Range :

0

0

- 40 C to +105 C (ISO 6722)

ü

Voltage : 60 V DC

ü

Thermal Life, Heat Shock,

Shrinkage, Ozone Resistance, Volume

Resistivity etc as per ISO 6722.

ü

Hot oil (ASTM1) : No breakdown at 1kV

ü

Battery Acid Resistance : <1% swell

ü

Auto Transmission Fluid (Dexon III) :

No breakdown at 1kV

0

ü

Hydrolysis : Pass (35 days, 85 C, 48V)

ü

Salt spray test as per ASTM B 117-73 :

Satisfactory

ü

Specifications : ISO 6722

ü

Meets customer specific pressure test

against water and different fluids,

solvents, oil etc.

ü

Conductor : Annealed Plain (or) Tinned Copper

Conductor

ü

Insulation : PVC 105°C

ü

Colour : As per customer order.

ü

Single core, Single layer.

ü

Anti capillary effect of high pressure hot oil Leaks

from Air condition compressors to circuit boards.

ü

These wires protects the vital sensors in

automobiles electronic devices in automobiles

by preventing the flow of liquids and fluids.

ü

This replaces the conventional usage of

expensive water blocking and water proof

materials.

ü

Electron beam cross linked.

ü

Does not drip and soldering iron resistant

ü

Barrier- Sealed.

ü

High and low temperature resistance.

ü

Ozone and weathering resistance.

ü

Resistance to pressure at high temperature.

ü

Insulation is resistant to most of the oils used

in 2 wheelers, passenger cars, trucks and

oil leaks from AC compressors.

ü

Flame retardant.

ü

Abrasion resistance.

ü

Fluid block resistance.

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

Siechem

Class B Anti-capillary Wires

Siechem Class B Anti-capillary Wires

o

o

ü

Current Carrying capacity given is for the maximum conductor operating of 150 C and ambinet air temperature of 40 C.

ü

* Other length as per Customer order.

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Cable

Overall Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm kg/km

mm

Part

Number

mm

mm

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

Nom.

Min.

mm

mm

54.4

37.1

24.7

18.5

12.7

9.42

7.60

4.71

3.10

0.35

0.35

0.35

0.35

0.35

0.35

0.35

0.40

0.40

0.80

1.00

1.20

1.35

1.70

1.86

2.15

2.50

2.95

5

7

9

11

17

22

27

43

62

Current

Carrying

Capacity

Amps

10

12

19

21

27

33

38

51

66

0.35

0.5

0.75

1

1.5

2

2.5

4

6

0.27

0.19

0.24

0.27

0.33

0.38

0.41

0.55

0.67

7

19

19

19

19

19

19

19

19

1.20

1.40

1.70

1.90

2.20

2.50

2.70

3.40

4.00

1.30

1.50

1.80

2.00

2.30

2.65

2.90

3.50

4.20

1.40

1.60

1.90

2.10

2.40

2.80

3.00

3.70

4.30

Catalogue

No

Anti-capillary

B89505XX

B89506XX

B89508XX

B89510XX

B89513XX

B89514XX

B89516XX

B89519XX

B89523XX

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949