Application
Product Construction
Technical Data
Wires & Cables
Features
ü
It is mainly used in hybrid vehicles.
ü
Copper braid is used as shielding to
prevent the electromagnetic
influence on the environment.
ü
High flexibility.
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
A898
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
(max.)
Conductor Construction
Insulation
Thickness
(Nom)
Overall
Diameter
Weight
Approx.
Outer
Sheath
Thickness
(Nom)
2
mm nos.
mm kg/km
mm
Part
Number
mm
mm
Standard
Length*
mtrs
0
0
ü
T
emperature Range - 40 C to +150 C (3000 Hours)
ü
Voltage Rating (U /U) 600V AC / 1000V AC
0
ü
Test Voltage, 1min 3.5 kV AC / 8.4 kV DC
ü
Standard ISO 6722 , Class D
ü
Min. Bending Radius (fixed) 4 X Cable dia.
ü
Conductor : Soft-Annealed Electrolytic Plain
Flexible Copper Conductor
ü
Insulation : Sietherm 155
ü
Insulation Colour : White
ü
Screening : Annealed Tinned Copper
ü
Outer Sheath : AX 150
ü
Sheath Colour : Orange
122
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Ω/km
Max.
Conductor
Resistance
0
at 20 C
0.35
0.35
0.40
0.40
0.60
0.65
0.65
0.80
0.90
1.00
1.20
1.40
1.50
500
500
500
500
500
500
500
500
500
500
500
500
500
0.45
0.55
0.60
0.70
0.85
0.85
0.90
0.90
0.95
1.00
1.30
1.50
1.60
3.9 ± 0.3
5.0 ± 0.3
5.8 ± 0.3
6.6 ± 0.3
8.4 ± 0.3
9.8 ± 0.3
11.2 ± 0.3
12.7 ± 0.3
14.9 ± 0.3
17.0 ± 0.3
19.9 ± 0.4
22.6 ± 0.4
24.9 ± 0.5
33
50
70
100
155
230
330
450
620
850
1145
1450
1778
0.10
0.10
0.10
0.10
0.10
0.15
0.15
0.15
0.20
0.20
0.25
0.25
0.25
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
19
50
56
84
80
126
196
276
396
360
475
608
756
12.7
7.6
4.71
3.14
1.82
1.16
0.743
0.527
0.368
0.259
0.196
0.153
0.122
Screen
Wire dia
(Nom)
0.33
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
0.51
Siechem Single Core Screened EBXL 150 deg.C Cable
mm
:
:
:
:
:
A898130910
A898160910
A898190910
A898230910
A898270910
A898280910
A898300910
A898320910
A898340910
A898370910
A898380910
A898410910
A898420910
0
0
ü
Current carrying capacity given for the maximum conductor operating of 150 C and ambient temperature of 30 C.
Current
Carrying
Capacity
Amps
47
65
88
112
165
221
294
370
470
592
720
840
975
ü
Flame retardant.
ü
Excellent resistance to battery acids, diesel, various
oils, window washer fluids, ozone and weathering.
ü
Soldering iron resistant.
ü
Excellent high and low temperature resistant.
ü
Easy to strip and process.
ü
Heat resistant.
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949