Table of Contents Table of Contents
Previous Page  123 / 162 Next Page
Information
Show Menu
Previous Page 123 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Features

ü

It is mainly used in hybrid vehicles.

ü

Copper braid is used as shielding to

prevent the electromagnetic

influence on the environment.

ü

High flexibility.

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

A898

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

(max.)

Conductor Construction

Insulation

Thickness

(Nom)

Overall

Diameter

Weight

Approx.

Outer

Sheath

Thickness

(Nom)

2

mm nos.

mm kg/km

mm

Part

Number

mm

mm

Standard

Length*

mtrs

0

0

ü

T

emperature Range - 40 C to +150 C (3000 Hours)

ü

Voltage Rating (U /U) 600V AC / 1000V AC

0

ü

Test Voltage, 1min 3.5 kV AC / 8.4 kV DC

ü

Standard ISO 6722 , Class D

ü

Min. Bending Radius (fixed) 4 X Cable dia.

ü

Conductor : Soft-Annealed Electrolytic Plain

Flexible Copper Conductor

ü

Insulation : Sietherm 155

ü

Insulation Colour : White

ü

Screening : Annealed Tinned Copper

ü

Outer Sheath : AX 150

ü

Sheath Colour : Orange

122

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Ω/km

Max.

Conductor

Resistance

0

at 20 C

0.35

0.35

0.40

0.40

0.60

0.65

0.65

0.80

0.90

1.00

1.20

1.40

1.50

500

500

500

500

500

500

500

500

500

500

500

500

500

0.45

0.55

0.60

0.70

0.85

0.85

0.90

0.90

0.95

1.00

1.30

1.50

1.60

3.9 ± 0.3

5.0 ± 0.3

5.8 ± 0.3

6.6 ± 0.3

8.4 ± 0.3

9.8 ± 0.3

11.2 ± 0.3

12.7 ± 0.3

14.9 ± 0.3

17.0 ± 0.3

19.9 ± 0.4

22.6 ± 0.4

24.9 ± 0.5

33

50

70

100

155

230

330

450

620

850

1145

1450

1778

0.10

0.10

0.10

0.10

0.10

0.15

0.15

0.15

0.20

0.20

0.25

0.25

0.25

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

19

50

56

84

80

126

196

276

396

360

475

608

756

12.7

7.6

4.71

3.14

1.82

1.16

0.743

0.527

0.368

0.259

0.196

0.153

0.122

Screen

Wire dia

(Nom)

0.33

0.26

0.31

0.31

0.41

0.41

0.41

0.41

0.41

0.51

0.51

0.51

0.51

Siechem Single Core Screened EBXL 150 deg.C Cable

mm

:

:

:

:

:

A898130910

A898160910

A898190910

A898230910

A898270910

A898280910

A898300910

A898320910

A898340910

A898370910

A898380910

A898410910

A898420910

0

0

ü

Current carrying capacity given for the maximum conductor operating of 150 C and ambient temperature of 30 C.

Current

Carrying

Capacity

Amps

47

65

88

112

165

221

294

370

470

592

720

840

975

ü

Flame retardant.

ü

Excellent resistance to battery acids, diesel, various

oils, window washer fluids, ozone and weathering.

ü

Soldering iron resistant.

ü

Excellent high and low temperature resistant.

ü

Easy to strip and process.

ü

Heat resistant.

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949