![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0127.jpg)
Application
Product Construction
Technical Data
Wires & Cables
CBBT 0.75
Sq.mmT3
Siechem
CBBT (T3)
Features
ü
Low-tension electric wire for automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Heat resistance
ü
Halogen free
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
Y802
0
0
ü
Temperature Range : -40 C to + 125 C
ü
Specification : MS 90034 & ISO 6722-1
C - Temperature Class C
B - Asymmetrical
B - Bare Copper
T - Thin Wall
ü
Conductor : Soft-annealed electrolytic bare
Copper according to ISO 6722
ü
Cable construction according to
ISO 6722 Class C (Thin wall)
ü
Insulation : Electron Beam Cross Linked
Polyolefin 125°C
ü
Colour : As per customer order.
ü
Single core, Single layer insulation
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
Max/Min.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
Current
Carrying
Capacity
mm
mm
Amps
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
Y80205XX
Y80206XX
Y80208XX
Y80210XX
Y80213XX
Y80214XX
Y80216XX
Y80217XX
Y80219XX
Y80221XX
Y80223XX
Y80225XX
Y80227XX
Y802A11XX
Y80228XX
Y80256XX
Y80230XX
54.4
37.1
24.7
18.5
12.7
9.42
7.60
6.15
4.71
3.94
3.14
2.38
1.82
1.52
1.16
0.995
0.743
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
12
16
24
32
30
28
50
44
56
65
84
50
80
96
126
152
196
0.21
0.21
0.21
0.21
0.26
0.31
0.26
0.31
0.31
0.33
0.31
0.46
0.41
0.41
0.41
0.41
0.41
0.9
1.1
1.3
1.5
1.8
2.0
2.2
2.4
2.8
3.1
3.4
4.3
4.5
5.4
5.8
6.9
7.2
0.35
0.5
0.75
1
1.5
2
2.5
3
4
5
6
8
10
12
16
20
25
0.25
0.28
0.30
0.30
0.30
0.35
0.35
0.40
0.40
0.40
0.40
0.40
0.60
0.60
0.65
0.65
0.65
1.20/1.40
1.40/1.60
1.70/1.90
1.90/2.10
2.20/2.40
2.50/2.80
2.70/3.00
3.10/3.40
3.40/3.70
3.90/4.20
4.00/4.30
4.60/5.00
5.30/6.00
5.80/6.50
6.40/7.20
7.00/7.80
7.90/8.70
5
7
10
11
17
23
25
35
43
54
59
82
105
135
167
208
245
12
15
20
24
30
37
42
49
58
66
75
92
107
122
142
158
184
126
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949