Application
Product Construction
Technical Data
Wires & Cables
Siechem
FLR12Y - A RoHS
FLR12Y - A
Features
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol and diesel.
ü
Excellent mechanical properties
ü
Fuel resistance
ü
Excellent thermal stability
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
A893
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Nom.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Min.
2
mm
nos.
mm kg/km
mm
Part
Number
mm
mm
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 150 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
Standard
Length*
500
500
500
500
500
500
500
mtrs
ü
Temperature Range :
0
0
- 40 C to +150 C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
FL : Automotive cable
ü
R : Reduced wall thickness
ü
12Y : Thermoplastic Polyester Elastomer
ü
A : Symmertical
ü
Standard : ISO 6722, Class D
ü
Insulation : TPE- E (Thermoplastic Polyester
Elastomer)
ü
Colour : As per customer order.
ü
Single core
E-Cu ETP1 according to DIN 13602, bare conductor
ü
Conductor : Soft-annealed electrolytic Copper
92
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
A89302XX
A89305XX
A89306XX
A89308XX
A89310XX
A89313XX
A89316XX
0.22
0.35
0.5
0.75
1
1.5
2.5
7
7
19
19
19
19
19
0.20
0.26
0.19
0.23
0.26
0.32
0.41
0.6
0.80
1.00
1.20
1.35
1.70
2.20
0.20
0.20
0.22
0.24
0.24
0.24
0.28
1.2
1.3
1.6
1.9
2.1
2.4
3.0
3
5
6
9
11
16
26
Ω/km
84.8
54.4
37.1
24.7
18.5
12.7
7.6
Max.
Conductor
Resistance
0
at 20 C
Current
Carrying
Capacity
Amps
10
11
14
18
22
28
40
119
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949