All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
848
www.siechem.comApplication
Product Construction
Technical Data
Features
Wires & Cables
ü
Temperature Range :
- 65˚C to +210˚C (3000 Hours)
2
ü
Test Voltage : 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
FL : Automotive Cable
ü
R : Reduced wall thickness
ü
6Y : Fluorinated Ethylene Propylene
ü
A : Symmetrical (Structure A)
ü
Standard : ISO 6722, Class F
LV 112-1
VW 60306-1
PSA 1325 1110
ü
Conductor : Soft-annealed electrolytic Copper
E-Cu - ETP1 according to DIN 13602, bare conductor
(Symmetrical)
ü
Optional : Tinned
ü
Insulation : FEP (Fluorinated Ethylene Propylene),
(Thin wall)
ü
Colour : As per customer order.
ü
Single core
ü
Suitable for inside engine compartment
ü
Low-tension electric wire for automobiles
ü
Used in Motorcycles and other motor vehicles
for starting, charging, lighting, signal and
instrument panel circuits
ü
Good mechanical and thermal properties
ü
Excellent chemical resistance
ü
Very good oil and fuel resistance
ü
High resistance to atmospheric conditions
and ozone
Siechem
FLR6Y- A (Auto 210 F-A) RoHS
Catalogue
No
FLR6Y-A
(Auto 210 F-A)
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
o
o
ü
Current Carrying capacity given is for the maximum conductor operating of 210 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Min.
2
mm
nos.
kg/km
mm
Part
Number
mm
mm
Max.
Conductor
Resistance
0
at 20 C
Standard
Length*
Ω/km
mm
mtrs
Current
Carrying
Capacity
Amps
0.22
0.35
0.5
0.75
1.0
1.5
2.5
84802XX
84805XX
84806XX
84808XX
84810XX
84813XX
84816XX
7
7
19
19
19
19
37
0.21
0.27
0.19
0.24
0.27
0.33
0.28
0.70
0.90
1.10
1.30
1.50
1.80
2.20
0.20
0.20
0.22
0.24
0.24
0.24
0.28
1.20
1.30
1.60
1.90
2.10
2.40
3.00
3
5
6
9
11
16
25
11
14
19
25
30
38
54
84.8
54.4
37.1
24.7
18.5
12.7
7.60
500
500
500
500
500
500
500
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949
117