53
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Wires & Cables
Product Construction
Technical Data
ü
Conductor : Annealed Plain Copper
Conductor according to ISO 19642 (Stranded)
ü
Insulation : Electron Beam Cross Linked
Polyolefin Class C (Thin wall)
ü
Insulation Colour : As per ISO 19642-1
ü
Screening : Annealed Tinned Copper
Conductor
ü
Sheath : Electron Beam Crossed Linked
Polyolefin
ü
Sheath Colour : Orange (or) As Per
Customer Order
Siechem
Single Core Screened, Stranded Class C (Thin) 1000V AC EV 125 Cable
2D View
Nominal
Cross-
Section
No. of
Strands
Stand dia.
(Max)
Conductor Construction
Over all Diameter
Weight
Approx.
Insulation
Thickness
2
mm nos.
kg/km
mm
Part
Number
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
(Min.)
mm
mm
Current
Carrying
Capacity
Amps
mm
12.7
9.42
7.6
6.15
4.71
3.94
3.14
2.38
1.82
1.52
1.16
0.955
0.743
0.647
0.527
0.473
0.368
0.315
0.259
0.219
0.196
Min.
Max.
1C x 1.5
1C x 2
1C x 2.5
1C x 3
1C x 4
1C x 5
1C x 6
1C x 8
1C x 10
1C x 12
1C x 16
1C x 20
1C x 25
1C x 30
1C x 35
1C x 40
1C x 50
1C x 60
1C x 70
1C x 85
1C x 95
19
19
37
44
56
70
84
116
144
174
228
276
355
408
501
558
717
838
1019
1197
1347
0.33
0.38
0.30
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.24
0.28
0.28
0.32
0.32
0.32
0.32
0.32
0.48
0.48
0.52
0.52
0.52
0.64
0.64
0.71
0.71
0.80
0.80
0.90
0.90
33
41
46
58
68
85
95
130
160
180
235
270
340
390
470
520
645
740
810
1035
1145
0
0
ü
Rated Temperature : - 40 C to +125 C (3000 Hours)
ü
Max. Rated Voltage : 1000V AC / 1500V DC
ü
Test Voltage : 10kV AC for 5 mins (≥ 0.5 Sqmm)
ü
Insulation Faults : 8kV AC
ü
Specification : ISO 19642-9, ISO 6722, Generally
as per QC / T 1037-2016**
mm
0.13
0.13
0.13
0.16
0.16
0.16
0.16
0.19
0.19
0.19
0.19
0.19
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.26
0.26
Sheath
Thickness
(Nom.)
A95613XXYY
A95614XXYY
A95616XXYY
A95617XXYY
A95619XXYY
A95621XXYY
A95623XXYY
A95625XXYY
A95627XXYY
A956A11XXYY
A95628XXYY
A95656XXYY
A95630XXYY
A95657XXYY
A95632XXYY
A95658XXYY
A95634XXYY
A95635XXYY
A95637XXYY
A95659XXYY
A95638XXYY
3.3
3.7
3.9
4.2
4.5
5.4
5.5
6.5
7.5
8.0
9.0
9.6
10.7
11.6
12.6
13.3
14.6
15.5
16.6
18.2
19.1
0.40
0.40
0.40
0.40
0.40
0.60
0.60
0.65
0.65
0.65
0.80
0.80
0.90
0.90
1.00
1.00
1.10
1.10
1.10
1.10
1.10
mm
Screen
Wire dia
(Max.)
3.7
4.1
4.3
4.8
5.1
6.0
6.1
7.1
8.1
8.6
9.6
10.2
11.3
12.2
13.2
13.9
15.2
16.3
17.4
19.0
19.9
Note : XX*YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX,YY while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
o
o
ü
Current Carrying capacity given is for the maximum conductor operating of 125 C and
ambient
air temperature of 40 C.
ü
** Conductor construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/ T1037-2016 or any specific construction, the same can also be supplied.
35
42
49
56
66
74
85
103
120
135
162
188
213
235
263
290
327
370
418
475
516
A956
Catalogue
No
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949
Application
Features
ü
Electrical vehicle charging station
ü
Portable cables for hybrid & electric vehicles
ü
Designed to be installed (both indoors
and outdoors) at private homes, communal
blocks, companies & other places
ü
Enchanced DV power rating makes it ideal
for high powered charging stations
ü
Designed to be installed in public access
environment likes urban spaces, shopping
centre, car park, airport etc.
ü
Suitability for installation with possibility of
water immersion
ü
Designed for harsh mechanical environments.
ü
Chemical and abrasion resistant.
ü
Hydrolyse resistant.
ü
Thermal stress resistant.
ü
Halogen free.
ü
Flame resistant.
ü
High flexibility and easy to use.
ü
Light weight, thin diameter.
ü
Cable is constructed to prevent injury and leakage.
ü
Low corrosive gas emission.