58
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Wires & Cables
Product Construction
Technical Data
ü
Conductor : Annealed Plain Copper
Conductor according to ISO 19642 (Flexible)
ü
Insulation : Electron Beam Cross Linked
Polyolefin Class D (Thick Wall)
ü
Insulation Colour : As per ISO 19642-1
ü
Screening : Annealed Tinned Copper
Conductor
ü
Sheath : Electron Beam Crossed Linked
Polyolefin
ü
Sheath Colour : Orange (or) As Per
Customer Order
Siechem
Single Core Screened, Flexible Class D (Thick) 1000V AC EV 150 Cable
2D View
Nominal
Cross-
Section
No. of
Strands
Stand dia.
(Max)
Conductor Construction
Over all Diameter
Weight
Approx.
Insulation
Thickness
2
mm nos.
kg/km
mm
Part
Number
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
(Min.)
mm
mm
Current
Carrying
Capacity
Amps
mm
12.7
9.42
7.60
6.15
4.71
3.94
3.14
2.38
1.82
1.52
1.16
0.955
0.743
0.647
0.527
0.473
0.368
0.315
0.259
0.219
Min.
Max.
1C x 1.5
1C x 2
1C x 2.5
1C x 3
1C x 4
1C x 5
1C x 6
1C x 8
1C x 10
1C x 12
1C x 16
1C x 20
1C x 25
1C x 30
1C x 35
1C x 40
1C x 50
1C x 60
1C x 70
1C x 85
182
245
140
160
224
250
189
240
320
380
512
610
790
903
1102
1235
1600
1841
2147
2660
0.11
0.11
0.16
0.16
0.16
0.16
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.48
0.48
0.56
0.56
0.64
0.64
0.64
0.64
0.80
0.80
0.80
0.88
1.04
1.04
1.04
1.12
1.20
1.20
1.20
1.28
0
0
ü
Rated Temperature : - 40 C to +150 C (3000 Hours)
ü
Max. Rated Voltage : 1000V AC / 1500V DC
ü
Test Voltage : 10kV AC for 5 mins (≥ 0.5 Sqmm)
ü
Insulation Faults : 8kV AC
ü
Specification : ISO 19642-9, ISO 6722, Generally
as per QC / T 1037-2016**
mm
0.13
0.13
0.13
0.16
0.16
0.16
0.16
0.19
0.19
0.19
0.19
0.19
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.26
Sheath
Thickness
(Nom.)
A96113XXYY
A96114XXYY
A96116XXYY
A96117XXYY
A96119XXYY
A96121XXYY
A96123XXYY
A96125XXYY
A96127XXYY
A961A11XXYY
A96128XXYY
A96156XXYY
A96130XXYY
A96157XXYY
A96132XXYY
A96158XXYY
A96134XXYY
A96135XXYY
A96137XXYY
A96159XXYY
4.9
5.2
5.5
6.1
6.6
7.1
7.2
8.5
9.1
10.2
11.1
12.1
13.4
14.1
14.8
15.6
16.7
17.8
18.9
20.4
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.6
1.6
1.7
mm
Screen
Wire dia
(Max.)
5.3
5.6
6.1
6.7
7.2
7.7
7.8
9.1
9.7
10.8
11.7
12.7
14.0
14.7
15.4
16.2
17.5
18.6
19.7
21.2
Note : XX*YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX,YY while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
o
o
ü
Current Carrying capacity given is for the maximum conductor operating of 150 C and
ambient
air temperature of 40 C.
ü
** Conductor construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/ T1037-2016 or any specific construction, the same can also be supplied.
35
42
49
56
66
74
85
103
120
135
162
188
213
235
263
290
327
370
418
475
A961
Catalogue
No
53
60
74
84
105
115
130
165
210
240
295
345
435
485
560
620
775
860
970
1200
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949
Application
Features
ü
Electrical vehicle charging station
ü
Portable cables for hybrid & electric vehicles
ü
Designed to be installed (both indoors
and outdoors) at private homes, communal
blocks, companies & other places
ü
Enchanced DV power rating makes it ideal
for high powered charging stations
ü
Designed to be installed in public access
environment likes urban spaces, shopping
centre, car park, airport etc.
ü
Suitability for installation with possibility of
water immersion
ü
Designed for harsh mechanical environments.
ü
Chemical and abrasion resistant.
ü
Hydrolyse resistant.
ü
Thermal stress resistant.
ü
Halogen free.
ü
Flame resistant.
ü
High flexibility and easy to use.
ü
Light weight, thin diameter.
ü
Cable is constructed to prevent injury and leakage.
ü
Low corrosive gas emission.