Table of Contents Table of Contents
Previous Page  70 / 162 Next Page
Information
Show Menu
Previous Page 70 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Auto 125- TW

Features

ü

Low-tension electric wire for automobiles.

ü

Used in motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Especially used for circuits requiring heat resistance.

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

A811

Siechem

Auto 125 - TW RoHS

69

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

max.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm nos.

mm

mtrs

kg/km

mm

Standard

Length*

Part

Number

mm

mm

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

o

o

ü

Current Carrying capacity given is for the maximum conductor operating of 125 C and ambient air temperature of 40 C.

ü

Cables are also available in dual colored insulation

ü

* Other length as per Customer order.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

Class

A B C D E F G H

o

o

o

o

o

o

o

o

+85 C +100 C +125 C +150 C +175 C +200 C +225 C +250 C

Temperature

o

from -40 C to

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

Max.

Conductor Construction

Conduct r

Diameter

Max.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulatio

Wall Thickness

Nom.

Standard

Length*

*

Max.

Conductor

Resistanc

0

at 20 C

Class

A B C D E F H

0.35

0.50

0.75

1

1.5

2

2.5

3

4

5

6

10

16

25

7

19

19

19

19

19

37

37

37

37

37

63

105

154

0.27

0.19

0.24

0.27

0.33

0.38

0.28

0.34

0.38

0.43

0.45

0.46

0.46

0.46

0.90

1.10

1.30

1.50

1.80

2.00

2.20

2.40

2.80

3.10

3.40

4.50

6.30

7.80

0.25

0.28

0.30

0.30

0.30

0.35

0.35

0.40

0.40

0.40

0.40

0.60

0.65

0.65

1.40

1.60

1.90

2.10

2.40

2.80

3.00

3.40

3.70

4.20

4.30

6.00

7.20

8.70

5

6

9

11

17

23

26

34

42

53

60

106

177

249

54.4

37.1

24.7

18.5

12.7

9.42

7.60

6.15

4.71

3.94

3.14

1.82

1.16

0.743

2000

2000

2000

2000

2000

2000

2000

1000

1000

1000

1000

1000

1000

1000

A81105XX

A81106XX

A81108XX

A81110XX

A81113XX

A81114XX

A81116XX

A81117XX

A81119XX

A81121XX

A81123XX

A81127XX

A81128XX

A81130XX

Cables confirming to the below categories are also available according to customer requirement

Conductor Configuration : Symmetrical, Asymmetrical, Flexible

Insulation thickness : Standard, Thin wall & Ultra thin wall

ISO 6722 Temperature Class Rating :

ü

Conductor : Soft /annealed Plain Copper

according to ISO 6722 (Symmetrical)

ü

Insulation : Electron beam crossed Linked

Polyolefin Class C

ü

Colour : As per customer order

ü

Cable construction according to ISO 6722,

Class C (Thin wall)

ü

Single core, Single layer insulation

0

0

ü

Temperature Range: -40 C to +125 C

(3000 Hours)

ü

Standard : ISO 6722 Class C (Thin wall)

ü

Operating Voltage :

(i) (60 V DC (or) 25 V AC) (or)

(ii) (600V DC (or) 600 V AC)

2

ü

Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm

2

5kV (r.m.s.) for cables ≥ 0.5 mm

ü

Excellent Flame retardant

ü

Highly resistant against acids, alkali, petrol and diesel

ü

Extra flexible conductors with Electron beam cross

linked polyolefin thin wall insulation for smaller

diameter and lesser weight

ü

Excellent flexibility

ü

Heat resistant

ü

Halogen free

Current

Carrying

capacity

Amps

12

15

20

24

30

37

42

49

58

66

75

108

144

189

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949