Table of Contents Table of Contents
Previous Page  69 / 162 Next Page
Information
Show Menu
Previous Page 69 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Siechem

Auto 125 RoHS

Auto 125

Features

ü

Low-tension electric wire for automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Heat resistance

ü

Halogen free

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

A810

ü

Temperature Range :

0

0

-40 C to + 125 C (3000 Hours)

2

ü

Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm

2

5kV (r.m.s.) for cables ≥ 0.5 mm

ü

Specification : ISO 6722

ü

Conductor : Soft-annealed electrolytic bare

Copper according to ISO 6722

ü

Cable construction according to

ISO 6722 Class C(thick wall)

ü

Insulation :Electron Beam Crossed linked

Polyolefin Class C

ü

Colour : As per customer order.

ü

Single core, Single layer insulation

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

mm

Amps

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

0.5

0.75

1

1.5

2

2.5

3

4

5

6

10

16

25

35

50

70

95

120

A81006XX

A81008XX

A81010XX

A81013XX

A81014XX

A81016XX

A81017XX

A81038XX

A81021XX

A81023XX

A81027XX

A81028XX

A81030XX

A81032XX

A81034XX

A81037XX

A81038XX

A81041XX

0.6

0.6

0.6

0.6

0.6

0.7

0.7

0.8

0.8

0.8

1

1

1.3

1.3

1.5

1.5

1.6

1.6

2.3

2.5

2.7

3

3.3

3.6

4.1

4.4

4.9

5

6.5

8.3

10.4

11.6

13.5

15.5

18

19.7

37.1

24.7

18.5

12.7

9.42

7.60

6.15

4.71

3.94

3.14

1.82

1.16

0.743

0.527

0.368

0.259

0.196

0.153

17

21

25

32

38

44

50

60

67

77

109

147

193

236

291

359

428

509

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

68

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

19

19

19

19

19

37

37

37

37

37

63

105

154

551

798

1140

836

1064

0.19

0.24

0.27

0.33

0.38

0.29

0.34

0.38

0.43

0.45

0.46

0.46

0.46

0.30

0.30

0.30

0.40

0.40

10

13

15

20

25

31

41

51

63

68

115

186

279

395

564

788

1037

1287

1.1

1.3

1.5

1.8

2.0

2.2

2.4

2.8

3.1

3.4

4.5

6.3

7.8

9.0

10.5

12.5

14.8

16.5

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949