Page Background

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

859

114

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Application

Product Construction

Technical Data

Wires & Cables

Siechem

FLRY11Y RoHS

FLRY11Y

Features

ü

Low-tension electric wire for Automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Flexible conductors with PVC insulation

with increased mechanical strength.

ü

Extra flexibility.

Wires & Cables

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

max.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm kg/km

mm

Part

Number

mm

mm

42

32

30

0.40

0.35

0.40

Standard

Length*

500

500

500

mtrs

ü

Temperature Range :

0

0

- 40 C to +105 C (3000 Hours)

2

ü

Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm

2

5kV (r.m.s.) for cables ≥ 0.5 mm

ü

FL : Automotive Cable

ü

R : Reduced wall thickness

ü

Y: PVC

ü

11Y: TPE-U Sheath

ü

Standard : ISO6722,Class B

ü

Insulation : PVC (Poly Vinyl Chloride)

ü

Outer Sheath : TPE-U (Thermoplastic polyurethane

elastomer with especially high resistance to hydrolysis)

ü

Colour : As per customer order.

ü

Multicore

E-Cu ETP1 according to DIN 13602, bare conductor

ü

Conductor : Soft-annealed electrolytic Copper

8590802

8591003

8591303

No. of

Core

2

mm

2

3

3

Max.

Conductor

Resistance

0

at 20 C

Ω/km

24.7

18.5

13.3

Sheath

Thickness

mm

0.8

0.7

0.75

5.6

6.0

6.9

47

54

71

0.75

1

1.5

0.16

0.21

0.26

1.2

1.5

1.7

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949