Table of Contents Table of Contents
Previous Page  113 / 162 Next Page
Information
Show Menu
Previous Page 113 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Siechem

FLR2X11Y RoHS

FLR2X11Y

Features

ü

Low-tension electric wire for Automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

ü

Flexible conductors with PVC thick wall insulation

with increased mechanical strength.

ü

Extra flexibility.

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

857

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Nom.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm kg/km

mm

Part

Number

mm

mm

Standard

Length*

500

500

500

500

mtrs

ü

Temperature Range :

0

0

- 40 C to +125 C (3000 Hours)

2

ü

Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm

2

5kV (r.m.s.) for cables ≥ 0.5 mm

ü

FL: Automotive cable

ü

R: Reduced wall Thickness

ü

2X: XLPE

ü

11Y: TPE-U

ü

Standard : ISO 6722, Class C

ü

Insulation : PE-X (Polyethylene cross linked)

ü

Outer Sheath : TPE-U (Thermoplastic polyurethane

elastomer with especially high resistance to

hydrolysis)

ü

Colour : As per customer order.

ü

Multicore

E-Cu ETP1 according to DIN 13602, bare conductor

ü

Conductor : Soft-annealed electrolytic Copper

8570502

8570602

8570602

8570802

112

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

0.35

0.5

0.5

0.75

No. of

Core

2

mm

2

2

2

2

0.25

0.3

0.3

0.5

3.9

4.6

4.6

6.4

Ω/km

mm

54.5

40.1

40.1

27.1

Ω/km

Bare

Tinned

52.0

37.1

37.1

24.7

Sheath

Thickness

0.5

0.65

0.65

0.9

Conductor

Resistance

0

at 20 C

25

35

36

63

0.21

0.19

0.16

0.16

0.9

1.0

1.0

1.2

12

19

28

42

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949