![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0111.jpg)
Application
Product Construction
Technical Data
Wires & Cables
FLRYDY
Features
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Flexible conductors with PVC thin wall insulation
with increased mechanical strength.
ü
Extra flexibility.
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
855
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Nom.
Cable
Overall
Diameter
Weight
Approx.
Nom.
Insulation
Wall Thickness
Nom.
2
mm nos.
mm kg/km
mm
Part
Number
mm
mm
0.75
1.0
1.5
Standard
Length*
500
500
500
mtrs
ü
Temperature Range :
0
0
- 40 C to +105 C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
FL : Automotive cable
ü
R : Reduced wall thickness
ü
Y : PVC
ü
D : Copper wire spiral Shield
ü
Y : PVC
ü
Standard : ISO 6722, Class B
ü
Insulation : PVC, according to ISO 6722,Class B
ü
Screen: ATC braiding
ü
Sheath: PVC, Lead free Class B
ü
Colour : As per customer order.
ü
Single core
E-Cu ETP1 according to DIN 13602, bare conductor
ü
Conductor : Soft-annealed electrolytic Copper
85508XXYY
85510XXYY
85513XXYY
Siechem
FLRYDY RoHS
110
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
2.7
2.9
3.2
0.3
0.3
0.3
1.2
1.35
1.7
0.21
0.21
0.26
24
32
30
Ω/km
24.7
18.5
12.7
Sheath wall
Thickness
mm
0.3
0.3
0.3
Max.
Conductor
Resistance
0
at 20 C
Amps
20
24
30
20
23
29
Current
Carrying
Capacity
Note : XX*YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX YY while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 105 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949