![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0108.jpg)
Application
Product Construction
Technical Data
Features
Wires & Cables
2D View
ü
Conductor : Soft-annealed electrolytic Copper
E-Cu ETP1 according to DIN 13602, bare or
tinned. Conductor construction according to
DIN 72551, Part 6, type B and ISO 6722.
ü
Insulation : Plasticized PVC with properties
according to DIN 72551 and ISO 6722,
Class B, Lead free.
ü
Colour : As per customer order.
ü
Temperature Range :
0
0
- 40 C to +105 C (3000 Hours)
ü
Standard : DIN 72551 - 6
BMW GS 95007-1
Ford WSK 1A348-A2
FIAT 91107/13
2
ü
Test Voltage : 3KV i.e <0.5mm
2
5KV i.e >0.5mm
ü
FL : Automotive cable, low voltage
ü
R : Reduced insulation wall thickness
ü
Y : PVC
ü
Type B: Flexible Conductor
ü
Conductor Resistance:IEC 60228/BS 6360
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel
ü
Flexible conductors with thin wall insulation
for extra flexibility.
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Cable
Overall Diameter
Weight
Approx.
Min.
Max.
Insulation
Wall Thickness
Nom.
Standard
Length*
Part
Number
ConductorResistance
0
at 20 C
Current
Carrying
Capacity
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
FLRY - B
2
mm nos.
mm mm
mtrs
kg/km
Ω/km
mm
mm
mm
Amps
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21 Black-White - D126
*
Nom.
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 105 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
818
Siechem
FLRY B RoHS
81805XX
81806XX
81808XX
81810XX
81813XX
81816XX
81819XX
81823XX
107
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
500
500
500
500
500
500
500
500
11
13
17
21
27
38
52
67
54.5
38.2
25.4
19.1
13.0
7.8
4.8
3.2
52.0
37.1
24.7
18.5
12.7
7.6
4.7
3.1
Ω/km
Bare
Tinned
Max.
5
6
9
12
17
28
43
63
1.20
1.40
1.70
1.90
2.20
2.70
3.40
4.30
1.40
1.60
1.90
2.10
2.40
3.00
3.70
4.30
0.20
0.22
0.24
0.24
0.24
0.28
0.32
0.32
0.9
1.0
1.20
1.35
1.70
2.20
2.75
3.30
0.21
0.21
0.21
0.21
0.26
0.26
0.31
0.31
12
16
24
32
30
50
56
84
0.35
0.5
0.75
1
1.5
2.5
4
6
OHSAS
18001
ISO
9001
ISO
14001
IATF
16949