![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0104.jpg)
Application
Product Construction
Technical Data
Wires & Cables
Siechem
FLR4Y-B RoHS
FLR4Y - B
Features
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Suitable as fuel gange wire
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Extra flexibility.
ü
Out standing fuel resistance
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
840
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
Max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Min.
2
mm
nos.
mm
kg/km
mm
Part
Number
mm
mm
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 105 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
Standard
Length*
500
500
500
500
500
500
500
500
mtrs
ü
Temperature Range :
0
0
- 40 C to +105 C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
FL : Automotive cable
ü
R : Reduced wall thickness
ü
4Y : Polyamide
ü
B : Asymmetrical (Structure B)
ü
Standard : ISO 6722, Class B
ü
Insulation : PA (Polyamide) (Thin Wall)
ü
Colour : As per customer order.
ü
Single core
E-Cu ETP1 according to DIN 13602, bare conductor
(Asymmetrical)
ü
Conductor : Soft-annealed electrolytic Copper
103
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
1.4
1.6
1.9
2.1
2.3
2.4
3.0
3.7
0.20
0.22
0.24
0.24
0.24
0.24
0.28
0.32
0.90
1.10
1.30
1.50
1.70
1.80
2.20
2.80
0.21
0.21
0.21
0.21
0.33
0.26
0.26
0.31
0.35
0.5
0.75
1
1.25
1.5
2.5
4
12
16
24
32
16
30
50
60
4
6
9
11
14
16
26
41
Ω/km
Max.
Conductor
Resistance
0
at 20 C
Current
Carrying
Capacity
Amps
10
13
18
21
25
27
38
52
54.4
37.1
24.7
18.5
14.9
12.7
7.60
4.71
A84005XX
A84006XX
A84008XX
A84010XX
A84012XX
A84013XX
A84016XX
A84019XX
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949