Table of Contents Table of Contents
Previous Page  105 / 162 Next Page
Information
Show Menu
Previous Page 105 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Siechem

FL91Y-FL11Y RoHS

FL91Y - FL11Y

Features

ü

Low-tension electric wire for Automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

852

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Nom.

Cable

Overall

Diameter Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm kg/km

mm

Part

Number

mm

mm

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 110 C and ambient air temperature of 40 C.

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

*

6

10

16

25

35

50

70

95

120

Standard

Length*

500

500

500

500

500

500

500

500

500

mtrs

ü

Temperature Range :

0

0

- 40 C to + 110 C (3000 Hours) - FL11Y

0

0

- 40 C to + 125 C (3000 Hours) - FL91Y

2

ü

Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm

2

5kV (r.m.s.) for cables ≥ 0.5 mm

ü

FL : Automotive cable

ü

91Y : TPE-O

ü

FL : Automotive cable

ü

11Y : TPE-U

ü

Standard : ISO 6722, Class C

ü

Insulation : FL11Y- TPE-U (Thermoplastic polyurethane

elastomer) according to ISO 6722, Class B

ü

FL91Y: TPE-O (thermoplastic polyolefin elastomer)

according to ISO 6722,Class C

ü

Colour : As per customer order.

ü

Single core

E-Cu ETP1 according to DIN 13602, bare conductor

ü

Conductor : Soft-annealed electrolytic Copper

85223XX

85227XX

85228XX

85230XX

85232XX

85234XX

85237XX

85238XX

85241XX

104

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

Ω/km

3.14

1.82

1.16

0.743

0.527

0.368

0.259

0.196

0.153

5.0

6.5

8.3

10.4

11.6

13.5

15.5

18.0

19.7

3.3

4.5

6.3

7.8

9.0

10.5

12.5

14.8

16.5

0.31

0.41

0.41

0.41

0.41

0.41

0.51

0.51

0.51

84

80

126

196

276

396

360

475

608

73

120

177

275

373

535

725

970

1205

Max.

Conductor

Resistance

0

at 20 C

0.80

1.00

1.00

1.30

1.30

1.50

1.50

1.60

1.60

Current

Carrying

Capacity

FL91Y FL11Y

Amps

Amps

77

110

148

195

238

294

362

429

493

72

102

137

181

220

273

336

398

457

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949