nos.
mm
74
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
Wires & Cables
Product Construction
Technical Data
Siechem
3C x 2.5 + 1C x 0.5
Sq.mmH07BZ6-F 450/750V EV Cable
2D View
Nominal
Cross-
Section
No. of
Strands
Stand dia.
(mm)
(Max.)
Conductor Construction
Sheath
Thickness
Nom.
Insulation
Thickness
2
mm
Part
Number
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
Nom.
mm
mm
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
7.98
4.95
3.30
1.91
1.21
0.780
0.554
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
0.7
0.7
0.7
0.7
0.7
0.9
0.9
0.7
0.7
0.7
0.7
0.7
0.9
0.9
9.2
10.5
12.1
13.7
16.3
19.4
24.2
28.4
11.6
13.4
15.2
18.1
21.7
27.0
31.7
12.9
14.9
16.9
20.3
24.2
30.2
35.6
11.8
13.5
15.5
17.5
20.8
24.9
30.9
36.3
14.9
17.2
19.4
23.2
27.7
34.5
40.6
16.5
19.1
21.7
25.9
31.0
38.7
45.5
Overall Diameter
1.5
1.6
1.7
1.9
2.1
2.4
2.8
3.2
1.7
1.9
2.0
2.3
2.6
3.1
3.5
1.8
2.0
2.2
2.5
2.8
3.4
3.9
Min.
Max.
(3C X 1.5)+0.5
(3C X 2.5)+0.5
(3C X 4)+0.5
(3C X 6)+0.5
(3C X 10)+0.5
(3C X 16)+0.5
(3C X 25)+0.5
(3C X 35)+0.5
(4C X 2.5)+0.5
(4C X 4)+0.5
(4C X 6)+0.5
(4C X 10)+0.5
(4C X 16)+0.5
(4C X 25)+0.5
(4C X 35)+0.5
(5C X 2.5)+0.5
(5C X 4)+0.5
(5C X 6)+0.5
(5C X 10)+0.5
(5C X 16)+0.5
(5C X 25)+0.5
(5C X 35)+0.5
30
50
56
84
80
126
196
276
50
56
84
80
126
196
276
50
56
84
80
126
196
276
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.26
0.31
0.31
0.41
0.41
0.41
0.41
www.siechem.comü
Conductor : Annealed Plain Copper Conductor
(Optional: Tinned) according to 60228
ü
Insulation : EVI-2
ü
Control cable : CP/CC (Control pilot/control core)
as per customer request
ü
Conductor : Annealed Plain Copper Conductor
ü
Insulation : EVI-2
ü
Sheath : EVM-2
ü
Sheath Colour : Orange (or) as per customer request
ü
Rated Temperature :
0
0
Static : - 40 C to +90 C
0
0
Dynamic : - 35 C to +90 C
ü
Rated Voltage : 450/750V
ü
Test Voltage : 3.5 KV AC
(1 Hour in water both)
ü
Bending Radius :
Static : 5 X Cable OD
Dynamic : 15 X Cable OD
ü
Specification : EN 50620 : 2017
A9771303XE
A9771603XE
A9771903XE
A9772303XE
A9772703XE
A9772803XE
A9773003XE
A9773203XE
A9771604XE
A9771904XE
A9772304XE
A9772704XE
A9772804XE
A9773004XE
A9773204XE
A9771605XE
A9771905XE
A9772305XE
A9772705XE
A9772805XE
A9773005XE
A9773205XE
mm
mm
Note :
ü
X - No. of Control Cable
ü
E - Earthing
A977
Catalogue
No
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949
Application
Features
ü
Electrical vehicle charging station
ü
Portable cables for hybrid & electric vehicles
ü
Designed to be installed (both indoors
and outdoors) at private homes, communal
blocks, companies & other places
ü
Enchanced DV power rating makes it ideal
for high powered charging stations
ü
Designed to be installed in public access
environment likes urban spaces, shopping
centre, car park, airport etc.
ü
Suitability for installation with possibility of
water immersion
ü
Designed for harsh mechanical environments.
ü
Chemical and abrasion resistant.
ü
Hydrolyse resistant.
ü
Thermal stress resistant.
ü
Halogen free.
ü
Flame resistant.
ü
High flexibility and easy to use.
ü
Light weight, thin diameter.
ü
Cable is constructed to prevent injury and leakage.
ü
Low corrosive gas emission.