![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0099.jpg)
Application
Product Construction
Technical Data
Wires & Cables
2D View
Siechem
FLRYW - A RoHS
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Nom.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm kg/km
mm
Part
Number
mm
mm
FLRYW-A
Features
ü
Low-tension electric wire for Automobiles.
ü
Suitable for application
inside the engine compartment
ü
Cold resistant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Flexible conductors with PVC thin wall insulation
ü
Heat resistant
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
A875
Standard
Length*
A87505XX
A87506XX
A87508XX
A87510XX
A87513XX
A87514XX
mtrs
ü
Temperature Range :
0
0
- 50 C to +125 C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
FL: Automotive cable
ü
R: Reduced wall thickness
ü
YW: Hot pressure type
ü
Standard : DBL 6312
Ford ES-AU5T-1A348
ü
Insulation : Soft PVC With properties
according to ISO 6722, Class C Lead free
ü
Colour : As per customer order.
ü
Single core
E-Cu ETP1 according to DIN EN 13602, bare conductor
ü
Conductor : Soft-annealed electrolytic Copper
98
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
7
19
19
19
19
19
0.26
0.19
0.23
0.26
0.32
0.38
0.8
1.0
1.2
1.35
1.7
2.0
1.3
1.6
1.9
2.1
2.4
2.8
5
6
9
11
16
22
0.35
0.5
0.75
1
1.5
2
0.20
0.22
0.24
0.24
0.24
0.28
500
500
500
500
500
500
54.4
37.1
24.7
18.5
12.7
9.42
Ω/km
Max.
Conductor
Resistance
0
at 20 C
Current
Carrying
Capacity
Amps
11
15
19
23
30
37
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949