Application
Product Construction
Technical Data
Wires & Cables
2D View
Siechem
FLYW RoHS
FLYW
Features
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
ü
Flexible conductors with PVC thick wall insulation
with increased mechanical strength.
ü
Extra flexibility.
0
ü
Hot pressure resistance test at 120 C
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
834
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Nom.
Cable
Overall
Diameter Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm kg/km
mm
Part
Number
mm
mm
*
0.5
0.75
1
1.5
2
2.5
3
4
6
10
16
25
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
Standard
Length*
500
500
500
500
500
500
500
500
500
500
500
500
mtrs
ü
Temperature Range :
0
0
- 40 C to +125 C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
FL : Automotive Cable
ü
YW : Heat & hot pressure resistance
ü
Standard : Bosch 598 341...
DBL 6312
ü
Insulation : Plasticized PVC with properties
according to ISO 6722, Class C, Lead free
ü
Colour : As per customer order.
ü
Single core
E-Cu ETP1 according to DIN 13602, bare conductor
ü
Conductor : Soft-annealed electrolytic Copper
94
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
83406XX
83408XX
83410XX
83413XX
83414XX
83416XX
83417XX
83419XX
83423XX
83427XX
83428XX
83430XX
16
24
32
30
28
50
60
56
84
80
126
196
0.21
0.21
0.21
0.26
0.31
0.26
0.26
0.31
0.31
0.41
0.41
0.41
1.0.
1.2
1.35
1.7
2.0
2.2
2.4
2.75
3.3
4.5
6.3
7.8
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.0
1.30
2.3
2.5
2.7
3.0
3.3
3.6
4.1
4.4
5.0
6.5
8.3
10.2
10
13
16
21
26
31
38
50
70
120
177
271
Max.
Conductor
Resistance
0
at 20 C
Current
Carrying
Capacity
Ω/km
Amps
37.1
24.7
18.5
12.7
9.42
7.6
6.0
4.71
3.14
1.82
1.16
0.743
16
21
25
32
38
44
50
59
76
108
146
191
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949