![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0037.jpg)
Application
Product Construction
Technical Data
Wires & Cables
2D View
Siechem
Low Voltage Auto Cables RoHS
ü
Temperature Range :
0
0
- 40 C to +70 C (3000 Hours)
ü
Standard : IS 2465
ü
Test Voltage : 3 kV
ü
Conductor Resistance: IS 8130
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Approx.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
Current
Carrying
Capacity
mm
mm
Amps
0.5
0.75
1
1.5
2.5
4
6
10
0.60
0.60
0.70
0.70
0.70
0.80
0.80
1.00
IS 2465
Features
ü
Low-tension electric wire for automobiles.
ü
Used in motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, petrol
and diesel.
ü
Flexible conductor with PVC battery cable insulation for
ü
Extra flexibility.
ü
Insulation : Lead free PVC.
ü
Colour : As per customer order.
ü
Single core
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
1000
1000
1000
1000
500
500
500
500
ü
* Other length as per Customer order.
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 70 C and ambient air temperature of 40 C.
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
ü
Conductor : Soft-annealed electrolytic copper
E-Cu ETP1 according to IS 8130, bare conductor
construction according to IS 2465
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
829
39.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
36
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
0.93
1.14
1.32
1.60
1.60
2.60
3.60
4.60
82906XX
82908XX
82910XX
82913XX
82916XX
82919XX
82923XX
82927XX
0.21
0.21
0.21
0.26
0.26
0.31
0.31
0.41
2.5
2.7
3.1
3.4
3.8
4.6
5.6
7.0
11
13
16
20
27
37
49
69
17
25
28
38
50
73
95
147
16
24
32
30
50
56
84
80
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949