![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0035.jpg)
Application
Product Construction
Technical Data
Wires & Cables
2D View
Siechem
HEB RoHS
ü
Temperature Range :
- 40°C to +80°C (3000 Hours)
ü
Standard : JASO D 611
ü
Test Voltage : 1 kV
ü
HEB : Heavy duty earth bond
Nominal
Cross-
Section
No. of
Strands/Dia
of stands
Nos.mmConductor
Diameter
Approx
Conductor Construction
Conductor
resistance
0
(20 C)
Cable
Overall Diameter
min
Insulation
Thickness
2
mm
nos.
mtrs
mm
Standard
Length*
Part
Number
mm
mm
HEB
Features
ü
Low-tension electric circuits of battery for automobiles.
ü
Used in elevated temperature enrolments
ü
Flame retardant
ü
Highly resistant against acids, lyes, petrol
and diesel.
ü
Flexible conductor with PVC thick wall insulation
with increased mechanical strength.
ü
Extra flexibility.
ü
Insulation : Lead free PVC.
ü
Colour : As per customer order.
ü
Single core
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
ü
* Other length as per Customer order.
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 80 C and ambient air temperature of 40 C.
*
ü
Conductor : Soft-annealed electrolytic copper
E-Cu ETP1 according to JIS C 3102, bare conductor
construction according to
JASO D 611
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
870
87014XX
87017XX
87021XX
87025XX
87026XX
87027XX
87055XX
87056XX
87057XX
87058XX
87034XX
87035XX
87059XX
87039XX
34
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
2
3
5
8
9
10
15
20
30
40
50
60
85
100
37/0.26
58/0.26
7/9/0.32
7/22/0.26
7/16/0.32
19/6/0.32
19/9/0.32
19/13/0.32
19/19/0.32
19/26/0.32
19/32/0.32
19/39/0.32
19/56/0.32
19/71/0.32
1.8
2.3
3.1
4.2
4.2
4.2
5.3
6.5
7.8
9.1
10.1
11.1
13.1
14.9
9.50
6.06
3.71
2.32
2.09
2.05
1.37
0.946
0.647
0.473
0.384
0.315
0.220
0.173
0.60
0.70
0.80
0.90
1.00
1.00
1.10
1.10
1.40
1.40
1.60
1.60
2.00
2.00
3.0
3.7
4.7
6.0
6.2
6.2
7.5
8.7
10.6
11.9
13.3
14.3
17.1
18.9
3.4
4.0
5.0
6.3
6.5
6.5
8.0
9.3
11.3
12.6
14.1
15.1
18.1
19.9
500
500
500
500
500
500
500
500
500
500
500
500
500
500
Max.
Nominal
Weight
Apporx
kg/km
mm
mm
25
36
60
91
103
105
151
209
313
415
516
615
884
1094
Current
Carrying
Capacity
Amps
27
36
50
69
73
73
95
120
150
181
208
239
307
365
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949