![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0032.jpg)
Application
Product Construction
Technical Data
Features
Wires & Cables
2D View
Siechem
CPE - FR RoHS
ü
Temperature Range :
0
0
- 40 C to +125 C (3000 Hours)
ü
Standards : ISO 6722-1
ü
CPE : Chlorinated polyethylene
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
Current
Carrying
Capacity
mm
mm
Amps
ü
Insulation : EBXL- CPE- FR (Thick wall)
ü
Colour : As per customer order.
ü
Single core
ü
Flame retardant
ü
Wear resistance, heat resistance
low temperature & good performance
ü
Low-tension electric wire for automobiles.
ü
Used in motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
CPE-FR
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
ü
* Other length as per Customer order.
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.
*
Max.
Conductor
Resistance
0
at 20 C
Ω/km
ü
Conductor : Soft-annealed electrolytic copper
E-Cu ETP1 according to DIN EN 13602, bare conductor
construction according to ISO 6722-1
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
826
82606XX
82608XX
82610XX
82613XX
82614XX
82616XX
82617XX
82619XX
82623XX
82627XX
82628XX
82630XX
82632XX
82634XX
82637XX
82638XX
82641XX
31
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
37.1
24.7
18.5
12.7
9.42
7.6
6.15
4.71
3.14
1.82
1.16
0.743
0.527
0.368
0.259
0.196
0.153
2.3
2.5
2.7
3.0
3.3
3.6
4.1
4.4
5.0
6.5
8.3
10.4
11.6
13.5
15.5
18.0
19.7
10
13
16
21
27
33
40
50
70
120
177
275
373
536
737
959
1206
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
17
22
26
32
39
445
513
61
78
110
149
195
239
300
384
475
562
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.0
1.3
1.3
1.5
1.5
1.6
1.6
0.5
0.75
1
1.5
2
2.5
3
4
6
10
16
25
35
50
70
95
120
16
24
32
30
28
50
44
56
84
80
126
196
276
396
360
475
608
0.21
0.21
0.21
0.26
0.31
0.26
0.31
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
1.1
1.3
1.5
1.8
2.0
2.2
2.4
2.8
3.4
4.5
5.8
7.2
8.5
10.5
12.5
14.8
16.5
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949