![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0042.jpg)
Application
Product Construction
Technical Data
Wires & Cables
Siechem
HDT RoHS
ü
Temperature Range :
0
0
- 40 C to +85 C (3000 Hours)
ü
Test Voltage : 1kV
ü
Specification :SAE J 1128
ü
HD : Heay Duty
ü
T : Thermoplastic Insulation
Size
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm
mtrs
kg/km
mm
Standard
Length*
Part
Number
mm
HDT
Features
ü
These cables designed for automotive
application required extra protection against
physical threats
ü
They are often used as surface in a variety of vehicles,
including cars, trucks, RVs, and buses.
ü
Extra protection
ü
Flexible
ü
Thick wall
ü
Insulation : PVC, Polyvinylchloride.
ü
Colour : As per customer order.
ü
Single core
Wires & Cables
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
ü
*Other length as per Customer order.
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 85 C and ambient air temperature of 40 C.
*
ü
Conductor : Soft annealed electrolytic copper
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
A881
A88106XX
A88160XX
A88110XX
A88111XX
A88117XX
A88121XX
A88125XX
41
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
0.5
0.8
1
2
3
5
8
7
16
19
19
19
19
19
0.31
0.26
0.29
0.36
0.45
0.57
0.71
0.91
0.94
1.02
1.04
1.17
1.17
1.40
3.1
3.4
3.7
4.2
5.1
5.7
7.0
14
20
25
33
49
71
98
500
500
500
500
500
500
500
Current
carrying
capacity
Amps
14
18
24
32
43
55
72
Max.
Conductor
Resistance
at 20°C
mm
35.7
22.7
15.4
9.3
5.9
3.7
2.4
Conductor
diameter
Nom.
mm
0.93
1.21
1.45
1.80
2.25
2.85
3.55
Catalogue
No
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949