Table of Contents Table of Contents
Previous Page  57 / 66 Next Page
Information
Show Menu
Previous Page 57 / 66 Next Page
Page Background www.siechem.com

Insulation

resistance:

1.0 Volume resistivity

at 27°C

Ohm cm

1 X 10

9

1 X 10

14

>1 X 10

14

>1 X 10

14

2.0

Volume resistivity

at 125°C

Ohm cm

Fails

Fails

>1 X 10

12

>1 X 10

12

3.0 Insulation resistance

at 27°C

Mohm km

36.7

>500

>500

>500

4.0

Insulation resistance

at 125°C

Mohm km

at 90°C (fails)

> 50

>50

1.0

High Voltage Test

after ageing of

complete cable :

1.1 Ageing temp.

°C

80

135

160

158

1.2 Duration

168 hrs ( 7 days )

168 hrs ( 7 days )

168 hrs ( 7 days )

168 hrs ( 7 days )

2.0 Test voltage

kV

3 kV for 5 minutes

3 kV for 5 minutes

6 kV for 5 minutes

6 kV for 5 minutes

3.0 Withstand test at

room temperature

3kV for 5 min

3kV for 5 min

6 kV for 5 min

6 kV for 5 min

4.0 Break down voltage

Min.

kV

<10

<10

18

18

5.0 Spark test

kV As per IS:694 test voltage As per IS:694 test voltage 25% higher than IS:694 test

voltage

25% higher than IS:694 test

voltage

Test Details

Conventional PVC Cables

as per IS:694/IS:1554

70°C

XLPE

(Chemical Curing)

90°C

Unit

Sl.

No

at 90°C (fails)

1.0

Smoke density

(ASTM D 2843)Max.

%

>80

NA

NA

10

2.0 Toxicity index

(NES 713)

%

>25

>10

>10

<5

3.0 Oxygen Index

%

29

>29

>29

>30

4.0 Acid gas emmission

(IEC 754 P-1)

%

>25 (fails)

NA

Nil

Nil

5.0

Temperature index

(ASTM D 2863)Min.

°C

160 (fails)

250

280

280

6.0 Sweedish Chimney

test

Pass

NA

Excellent

Excellent

6.1 Flammability as per

IEC 60332-1

6.1.1

Length of unaffected

portion from lower

edge of top clamp

mm

<50

300

300

>350

<60

<60

<20

<20

F) Electrical Properties

H) Fire Retardent Properities

Wires & Cables

EBXL - XLPO

0

12

5

C

EBXL - XLPE

0

12

5

C

56