Table of Contents Table of Contents
Previous Page  55 / 66 Next Page
Information
Show Menu
Previous Page 55 / 66 Next Page
Page Background www.siechem.com

54

Table 1: Comparative Study of EBXL XLPO Panel Wiring Cables Vs Others

Specification for Electron Beamed Single core, Unsheathed, Multi strand, Copper,

Flexible Wire Cables and Comparison between EBXL XLPO/XLPE, Vs Others (Chemically Cured Cables)

Sl.

No

Test Details

Unit

Conventional PVC Cables

as per IS:694/IS:1554

70°C

XLPE

(Chemical Curing)

90°C

EBXL - XLPO

0

12

5

C

A) Conductor

1.0 Material

Annealed Plain EC grade

flexible copper

Annealed Plain EC grade

flexible copper

Annealed Plain EC grade

flexible copper

Annealed Plain EC grade

flexible copper

2.0 No. of wires/dia

of wire

No/mm

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

3.0

Conductor

Diameter

mm

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

4.0 DC Resistance at

20°C

ohm/Km As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

As per IS:8130/84 or IEC

60228 : Class 5

1.0 Material

PVC Type A

Cross - linked Polyethylene

Electron Beam cross - linked

Polyolefin

2.0

Nominal

Thickness

mm Insulation thickness as per

IS:694 table for insulation

Upto 33% insulation thickness

less than that of IS:694 table

for insulation

Upto 33% Insulation thickness

less than that of IS:694 table

for insulation

Upto 33% Insulation thickness

less than that of IS:694 table

for insulation

3.0

Overall

diameter

of cable

mm

Conductor dia + (2 X t)

t=thickness of insulation

as per IS : 694

Conductor dia + (2 X t)

t=thickness of insulation

as per IS : 694

Conductor dia + (2 X t)

t=thickness of insulation

as per IS : 694

Conductor dia + (2 X t)

t=thickness of insulation

as per IS : 694

1.0 Continuous

operating Temp

0

C

70

90

125

125

2.0 Short circuit

Temperature

0

C

160

250

280

280 & 300

3.0 Soldering iron

Resistance

Melts and emit dark smoke

MeltsReasonably

Resistant & shall not melt Resistant & shall not melt

4.0 Ozone resistance

at complete cable

°C

%

h

%

NA

NA

NA

Temperature at 40 ± 2

Relative Humidity 55 ± 5

Duration 72

Ozone concentration

(200 ± 50) x 10¯6

Absence of cracks

5.0

Weathering / UV

-

Resistance

h

°C

%

W/m²

min

NA

NA

NA

Duration 720

Black Standard Temp. 63°C

Relative Humidity 65

Min. power at wavelength

300nm to 400nm is 60 ± 2

Duration spraying / drying

is 18/102

Absence of cracks.

Melts Reasonably

C) General

B) Insulation

Wires & Cables

Electron Beam Cross - linked

Polyethylene

EBXL - XLPE

0

12

5

C