2 & 3 Core Aluminium Conductor EBXL-XLPE 120°C Insulated, HR PVC Sheathed, (UA) UV Resistant

Power Cable

Operating Temperature : -15°C to +120°C

High Insulation resistance at elevated temperature

Short Circuit Temperature : 250°C

Bending radius (min) : 12 x Cable dia

Test Voltage : 3 kV for 5 mins.

Technical Data

Electron Beam Cross Linked. Does not melt or drip

Enhanced Mechanical, Electrical, Thermal & Weathering

properties.

Flame retardant

Excellent UV and Ozone resistant.

Specially designed for PV Power cable segment.

Features

Applications

PV Power cables

Transmission and distribution of Power

Industrial units

Commercial and residential places

Indoor and outdoor uses

Cable ducts, cable trays and conduits

Direct burial.

Catalogue

No

652E/653W

Wires & Cables

Construction:

Conductor

Insulation

Jacket

:

:

:

Aluminium conductor

complying with IS : 8130 - 1984

PVC ST 2 & UV Resistant complying with

IS : 5831 - 1984. (Colour Black)

Optional : 105°C HR PVC (UV)

0

Electron Beam Cross Linked Polyethylene 120 C

Specification : IS : 7098 (P-1) / 1988 (with enhanced operating temperature)

Siechem

offers 120°C

EBXL XLPE as against 90°C

offered by rest of the

competition

1

1

1

6

6

6

6

12

15

15

15

30

30

30

53

Short

Circuit

Rating

for 1 sec

Current Rating For EBXL - XLPE

Cables (120°C)

Max. D.C

Resistance

at 20 deg.C

Approx.

Capacitance

per phase

µF/Km

Conductor

Area

Cond. Min.

No. of

Wires

Thickness

of EBXL

XLPE

Insulation

(Nom.)

Thickness

of Outer

Sheath

(Nom.)

Approx.

Overall

Diameter

Approx.

Net Wt.

of Cable

Direct in

Ground

In Duct

In Air

Kg/Km

Amps

Amps

Amps

mm

mm

Part Number

Min.

Thickness

of PVC

Inner

Sheath

Sq.mm

Nos mm

mm

Ohm

/Km

KA

2Core 3Core

2Core 3Core 2Core 3Core

2Core 3Core

2Core 3Core

2Core 3Core

Note : To identify the number of cores in the cables, replace XX by 02 - for 2 Core Cable, 03 - for 3 Core Cable.

*

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

0.7

0.7

0.7

0.7

0.9

0.9

1.0

1.1

1.1

1.2

1.4

1.6

1.7

1.8

2.0

1.8

1.8

1.8

1.8

2.0

2.0

2.0

2.0

2.2

2.2

2.2

2.4

2.6

2.8

3.0

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.4

0.4

0.4

0.5

0.5

0.6

0.6

1.8

1.8

1.8

1.8

2.0

2.0

2.0

2.2

2.2

2.2

2.4

2.6

2.8

3.0

3.2

13.0

14.0

15.0

15.0

18.0

20.0

22.0

24.0

28.0

30.0

33.0

37.0

39.5

45.0

50.0

14

15

17

18

20

22

25

29

32

35

39

44

49

52

57

0.065

0.071

0.081

0.088

0.089

0.096

0.098

0.100

0.110

0.110

0.110

0.110

0.110

0.120

0.120

170

200

230

320

450

560

680

970

1220

1460

1880

2390

3000

3750

4760

150

200

230

280

320

390

480

630

820

990

1190

1490

1900

2360

2940

7.41

4.61

3.08

1.91

1.20

0.868

0.641

0.443

0.320

0.253

0.206

0.164

0.125

0.100

0.0778

50

63

84

110

140

168

198

244

290

330

373

418

483

546

606

44

54

71

92

117

141

168

207

246

278

315

354

408

462

513

43

54

71

92

116

139

165

204

239

272

306

344

396

446

495

37

45

59

76

97

116

136

168

199

224

255

284

326

369

410

46

59

79

108

127

160

194

250

304

355

410

469

556

642

714

38

49

69

91

114

142

173

221

269

311

360

411

484

558

619

0.38

0.57

0.94

1.5

2.4

3.3

4.7

6.6

9.0

11.3

14.2

17.5

22.6

28.3

37.7

652E19XX

652E23XX

652E27XX

653W28XX

653W30XX

653W32XX

653W34XX

653W37XX

653W38XX

653W41XX

653W42XX

653W44XX

653W46XX

653W48XX

653W49XX

2Core 3Core

0.22

0.25

0.31

0.36

0.41

0.47

0.50

0.53

0.61

0.63

0.64

0.65

0.66

0.67

0.67

2Core 3Core

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.4

0.4

0.4

0.5

0.5

0.6

0.6

0.7

SiechemEBXLXLPE 120°CAluminium (UA)PowerCable

TUV

AS

9100

ISO

45001

ISO

9001

ISO

14001