Table of Contents Table of Contents
Previous Page  38 / 66 Next Page
Information
Show Menu
Previous Page 38 / 66 Next Page
Page Background www.siechem.com

37

Single Core Aluminium Conductor EBXL-XLPE 120°C Insulated, HR PVC Sheathed (A) UV Resistant

Power Cable

Construction:

Operating Temperature : -15°C to +120°C

High Insulation resistance at elevated temperature

Short Circuit Temperature : 250°C

Bending radius (min) : 12 x Cable dia

Test Voltage : 3 kV for 5 mins.

Technical Data

Conductor

Insulation

Jacket

:

:

:

Aluminium conductor

complying with IS : 8130 - 1984

PVC ST 2 & UV Resistant complying with

IS : 5831 - 1984. (Colour Black)

Optional : 105°C HR PVC (UV)

Electron Beam Cross Linked Polyethylene 120°C

Electron Beam Cross Linked. Does not melt or drip

Enhanced Mechanical, Electrical, Thermal & Weathering

properties.

Flame retardant

Excellent UV and Ozone resistant.

Specially designed for PV Power cable segment.

Features

Applications

PV Power cables

Transmission and distribution of Power

Industrial units

Commercial and residential places

Indoor and outdoor uses

Cable ducts, cable trays and conduits

Direct burial.

Armour

: Non magnetic round wires

Rating factors for variation in ambient air temperature :

0

Temperature - C

Rating

Factors

Conductor

0

Temp. 120

C

20 25 30 35 40 45 50 55 60 65 70 75 80

1.12 1.09 1.06 1.03 1.00 0.97 0.94 0.91 0.88 0.83 0.79 0.75 0.71

Catalogue

No

654SRA/655SRA

Wires & Cables

Specification : IS : 7098 (P-1) / 1988 (with enhanced operating temperature)

Siechem

offers 120

°

C

EBXL XLPE as against 90°C

offered by rest of the

competition

Note : Please replace XX in the part number as per the colour code given hereunder.

Red - 01

Yellow - 02

Blue - 03

Black - 04

Green - 05

Yellow-Green - 06

Grey - 07

0

0

Current ratings given in this leaflet are calculated at an ambient air temperature 40 C and ground temperature 30 C

Short

Circuit

Rating

for 1 sec

Current Rating

For EBXL - XLPE

Cables (120°C)

Max. D.C

Resistance

at 20 deg.C

Approx.

Capacitance

per phase

Conductor

Area

Cond. Min.

No. of

Wires

Thickness

of EBXL

XLPE

Insulation

(Nom.)

Thickness

of Outer

Sheath

(Min.)

Approx.

Overall

Diameter

Approx.

Net Wt.

of Cable

Direct in

Ground In Duct

In Air

Dimension

of

Arm Wire

(Nom.)

Sq.mm

Nos mm mm

Kg/Km

Ohm

/Km

KA

Amps Amps

Amps

mm

mm

µF/Km

Part Number

654SRA19XX04

654SRA23XX04

654SRA27XX04

655SRA28XX04

655SRA30XX04

655SRA32XX04

655SRA34XX04

655SRA37XX04

655SRA38XX04

655SRA41XX04

655SRA42XX04

655SRA44XX04

655SRA46XX04

655SRA48XX04

655SRA49XX04

655SRA50XX04

655SRA51XX04

0.38

0.57

0.94

1.5

2.4

3.3

4.7

6.6

9.0

11.3

14.2

17.5

22.6

28.3

37.7

47.2

59.4

-

-

0.32

0.38

0.380

0.423

0.464

0.518

0.587

0.616

0.607

0.604

0.657

0.689

0.696

0.716

0.745

7.41

4.61

3.08

1.91

1.20

0.868

0.641

0.443

0.320

0.253

0.206

0.164

0.125

0.100

0.0778

0.0605

0.0469

10.5

11.0

12.0

12.5

14.5

15.5

17.0

19.5

20.0

22.0

24.0

26.0

29.0

31.0

35.0

38.0

43.0

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.4

1.4

1.4

1.4

1.4

1.56

1.56

1.56

1.72

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.6

1.6

1.6

1.6

1.6

1.6

2.0

2.0

2.0

1.0

1.0

1.0

1.0

1.2

1.2

1.3

1.4

1.4

1.5

1.7

1.9

2.0

2.1

2.4

2.6

2.8

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

1

1

1

6

6

6

6

12

15

15

15

30

30

30

53

53

53

131

152

176

200

287

331

406

523

655

767

907

1067

1322

1522

2015

2465

2969

48

62

74

97

126

152

180

224

267

311

349

398

463

534

611

709

819

57

71

87

112

149

176

212

258

310

351

394

453

522

597

661

754

858

55

68

83

109

143

178

217

281

342

399

460

529

627

725

875

1013

1178

Siechem EBXL XLPE 120°C Aluminium (A) Power Cable

TUV

AS

9100

ISO

45001

ISO

9001

ISO

14001