![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0085.jpg)
Application
Product Construction
Technical Data
Wires & Cables
Siechem
Auto 180E-A RoHS
Auto 180E-A
FLR7Y-A
Features
ü
Low-tension electric wire for automobiles.
ü
Used in motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, petrol
and diesel.
ü
Good mechanical & thermal properties
ü
Excellent chemical resistance
ü
Extra flexibility.
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
846
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
Max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm kg/km
mm
Part
Number
mm
mm
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
0
0
ü
Current Carrying capacity given is for the maximum conductor operating temperature of 180 C and ambient air temperature of 40 C.
ü
* Other length as per Customer order.
*
0.35
0.5
0.75
1
1.5
2.5
7
19
19
19
19
19
Standard
Length*
1000
1000
1000
1000
1000
1000
mtrs
ü
Temperature Range :
0
0
- 65 C to +180 C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
Standard : ISO 6722 Class E (Thin Wall)
LV 112-1
ü
Insulation : ETFE ( Ethylene tetrafluoroethylene)
with properties according to ISO 6722-1 Class E
ü
Colour : As per customer order.
ü
Single core
ü
Conductor : Annealed plain flexible copper conductor
Conductor construction according to ISO 6722-1
84
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
1.3
1.6
1.9
2.1
2.4
3.0
Ω/km
54.4
37.1
24.7
18.5
12.7
7.60
0.27
0.19
0.24
0.27
0.33
0.41
6
8
12
14
20
31
Max.
Conductor
Resistance
0
at 20 C
0.25
0.28
0.30
0.30
0.30
0.35
Current
Carrying
Capacity
Amps
14
18
23
28
36
50
84605XX
84606XX
84608XX
84610XX
84613XX
84616XX
0.90
1.10
1.30
1.50
1.80
2.20
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949