![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0081.jpg)
Application
Product Construction
Technical Data
Wires & Cables
Siechem
Auto 125X-A / FLR2X-A RoHS
Auto 125X-A / FLR2X-A
Features
ü
Low-tension electric wire for Automobiles.
ü
Used in Motorcycles and other motor vehicles for
starting, charging, lighting, signal and instrument
panel circuits.
ü
Flame retardant
ü
Highly resistant against acids, lyes, Petrol
and diesel.
Wires & Cables
Siechem Wires & Cables Meet EU RoHS Directive
Lead
Free
Hg
Free
Cd
Free
6+
Cr
Free
PBB
Free
PBDE
Free
Catalogue
No
842
ü
Temperature Range :
- 40°C to +125°C (3000 Hours)
2
ü
Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm
2
5kV (r.m.s.) for cables ≥ 0.5 mm
ü
Standard : ISO 6722,Class C
ü
FL : Automotive Cable
ü
R : Reduced wall Thickness
ü
2X : Cross Linked PE
ü
A : Symmetrical
ü
Insulation : PE-X with properties according to
ISO 6722, Class C
ü
Colour : As per customer order.
ü
Single core
E-Cu ETP1 according to DIN 13602, bare conductor
ü
Conductor : Soft-annealed electrolytic Copper
80
www.siechem.comAll information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
OHSAS
18001
AS
9100
ISO
45001
ISO
9001
ISO
14001
IATF
16949
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor Construction
Conductor
Diameter
Max.
Cable
Overall
Diameter
Weight
Approx.
Max.
Insulation
Wall Thickness
Nom.
2
mm
nos.
mm kg/km
mm
Part
Number
mm
mm
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02
Blue - 03
Black - 04
Green - 05 Yellow-Green - 06 Grey - 07
Brown - 08
White - 09
Orange - 10
Violet - 11
Chocolate - 12
Tan - 13
Charcoal - 14
LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19
Purple - 20
Pink - 21
o
o
ü
Current Carrying capacity given is for the maximum conductor operating of 125 C and ambinet air temperature of 40 C.
ü
* Other length as per Customer order.
*
Standard
Length*
500
500
500
500
500
500
500
500
500
500
500
500
mtrs
1.2
1.3
1.6
1.9
2.1
2.4
2.8
3.0
3.4
3.7
4.2
4.3
0.25
0.25
0.28
0.30
0.30
0.30
0.35
0.35
0.40
0.40
0.40
0.40
0.21
0.27
0.19
0.24
0.27
0.33
0.38
0.28
0.34
0.38
0.43
0.45
0.70
0.90
1.10
1.30
1.50
1.80
2.00
2.20
2.40
2.80
3.10
3.40
84.8
54.4
37.1
24.7
18.5
12.7
9.42
7.60
6.15
4.71
3.94
3.14
Ω/km
3
5
7
9
12
17
23
27
36
43
55
60
Max.
Conductor
Resistance
0
at 20 C
Current
Carrying
Capacity
Amps
9
11
15
20
24
30
37
42
49
58
66
75
7
7
19
19
19
19
19
37
37
37
37
37
0.22
0.33
0.5
0.75
1
1.5
2
2.5
3
4
5
6
84202XX
84205XX
84206XX
84208XX
84210XX
84213XX
84214XX
84216XX
84217XX
84219XX
84221XX
84223XX