Auto 125X-A / FLR2X-A RoHS

Auto 125X-A / FLR2X-A

Features

ü

Low-tension electric wire for Automobiles.

ü

Used in Motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Flame retardant

ü

Highly resistant against acids, lyes, Petrol

and diesel.

Wires & Cables

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

842

ü

Temperature Range :

- 40°C to +125°C (3000 Hours)

2

ü

Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm

2

5kV (r.m.s.) for cables ≥ 0.5 mm

ü

Standard : ISO 6722,Class C

ü

FL : Automotive Cable

ü

R : Reduced wall Thickness

ü

2X : Cross Linked PE

ü

A : Symmetrical

ü

Insulation : PE-X with properties according to

ISO 6722, Class C

ü

Colour : As per customer order.

ü

Single core

E-Cu ETP1 according to DIN 13602, bare conductor

ü

Conductor : Soft-annealed electrolytic Copper

80

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

2

mm

nos.

mm kg/km

mm

Part

Number

mm

mm

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

o

o

ü

Current Carrying capacity given is for the maximum conductor operating of 125 C and ambinet air temperature of 40 C.

ü

* Other length as per Customer order.

*

Standard

Length*

500

500

500

500

500

500

500

500

500

500

500

500

mtrs

1.2

1.3

1.6

1.9

2.1

2.4

2.8

3.0

3.4

3.7

4.2

4.3

0.25

0.25

0.28

0.30

0.30

0.30

0.35

0.35

0.40

0.40

0.40

0.40

0.21

0.27

0.19

0.24

0.27

0.33

0.38

0.28

0.34

0.38

0.43

0.45

0.70

0.90

1.10

1.30

1.50

1.80

2.00

2.20

2.40

2.80

3.10

3.40

84.8

54.4

37.1

24.7

18.5

12.7

9.42

7.60

6.15

4.71

3.94

3.14

Ω/km

3

5

7

9

12

17

23

27

36

43

55

60

Max.

Conductor

Resistance

0

at 20 C

Current

Carrying

Capacity

Amps

9

11

15

20

24

30

37

42

49

58

66

75

7

7

19

19

19

19

19

37

37

37

37

37

0.22

0.33

0.5

0.75

1

1.5

2

2.5

3

4

5

6

84202XX

84205XX

84206XX

84208XX

84210XX

84213XX

84214XX

84216XX

84217XX

84219XX

84221XX

84223XX