Table of Contents Table of Contents
Previous Page  151 / 162 Next Page
Information
Show Menu
Previous Page 151 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Features

Wires & Cables

2D View

Siechem

ATEEXS RoHS

ü

Temperature Range :

- 40°C to +120°C (3000 Hours)

ü

Standard : ISO 6722

ü

Test Voltage : 5 kV for 5 minutes

ü

A : Automobiles

ü

T : Tinned annealed copper wire

ü

E : Electric Automobile

ü

EX : Halogen free irradiated cross-linked

Polyethylene (Insulation)

ü

S : with Shield

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Max.

Weight

Approx.

Max.

Insulation

Wall

Thickness

Nom.

Braiding

wire dia.

Outer

Sheath

Thickness

Overall dia

Diameter

2

mm nos.

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

mm mm mm mm

Amps

ü

Insulation : Electron beam cross linked

polyethylene.

ü

Screening : Tinned Copper

ü

Sheath : P C

ü

Single core

ü

Flame retardant.

ü

Highly resistant against acids, lyes, petrol

and diesel.

ü

Flexible conductor with Electron beam cross linked

polyethylene thin wall insulation for smaller diameter

and lesser weight.

ü

Heat resistant.

ü

High voltage and high current circuit in electric

vehicles

ü

High reliability

ü

Low cost

ü

High ecological solution

ATEEXS

Wires & Cables

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

ü

* Other length as per Customer order.

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 120 C and ambient air temperature of 40 C.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

ü

Conductor : Soft-annealed electrolytic copper

E-Cu ETP1 according to JIS C 3102, tinned

conductor construction

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

B732

150

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

1.60

1.44

0.999

0.684

0.500

0.375

122

134

161

201

241

282

215

235

305

415

565

715

Max.

5.40

5.70

6.90

8.30

9.60

10.50

1.0

1.0

1.1

1.3

1.4

1.5

0.18

0.18

0.18

0.18

0.18

0.18

0.8

0.8

0.8

0.8

1.2

1.2

10.8

11.4

12.5

14.3

16.4

17.5

12

15

20

30

40

50

154

171

247

367

494

798

0.33

0.33

0.33

0.33

0.33

0.30

1000

1000

1000

500

500

500

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949

B732A11XX

B73255XX

B73256XX

B73257XX

B73258XX

B73234XX