Table of Contents Table of Contents
Previous Page  146 / 162 Next Page
Information
Show Menu
Previous Page 146 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Siechem

PEEK RoHS

ü

Temperature Range :

- 65°C to +260°C

ü

Test Voltage :1kV for 1 Minutes

ü

Voltage : 600/1000 V

PEEK

Features

ü

Aerospace

ü

Nuclear plant

ü

Automotive

ü

Medical

ü

Marine

ü

Corrosive Chemical plants

Wires & Cables

ü

Conductor : Soft- Annealed Electrolytic Nickel Plated

Copper Wire (Optional :Tin - Plated Soft-Annealed

Electrolytic Copper Wire, Silver - Plated Soft-Copper wire)

ü

Insulation : PEEK (PolyEther Ether Ketone)

ü

Colour : Black (or) as per Customer order

ü

Single core

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

B685

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

OHSAS

18001

ISO

9001

ISO

14001

IATF

16949

ü

High Temperature Resistant

ü

Wear and Abrasion Resistant

ü

Very High Radiation Resistance

ü

Chemical and Fluid Resistance

ü

Toughest Dynamic Friction behaviour

ü

High Dielectric Strength with good Thermal properties

ü

Fire behaviour UL 94 V-0, Low Smoke, Halogen free

ü

Low water absorption

No. of

Strands

Diameter of

Single wire

Max.

Conductor

diameter

Nom.

Conductor Construction

Insulation

wall Thickness

Nom

Weight

Approx.

Overall

Diameter

Nos

mm

mm mm kg/km Amps

mm

Part

Number

mm

Current

Carrying

Capacity

Ω/km

138.4

85.0

52.5

32.0

20.0

15.6

12.7

9.8

8.0

6.2

5.2

4.1

1.40

1.55

1.70

1.90

2.15

2.35

2.50

2.70

2.90

3.20

3.40

4.25

1.50

1.65

1.80

2.00

2.25

2.55

2.70

2.90

3.10

3.40

3.60

4.45

3

4

6

9

13

16

19

23

28

34

42

67

3

4

7.3

11

16

22

26

32

35

41

45

55

0.30

0.30

0.35

0.35

0.35

0.35

0.40

0.40

0.40

0.40

0.45

0.45

0.51

0.64

0.81

1.02

1.27

1.45

1.60

1.83

2.00

2.31

2.50

3.35

0.10

0.13

0.16

0.20

0.25

0.29

0.32

0.36

0.40

0.45

0.50

0.65

19

19

19

19

19

19

19

19

19

19

19

19

Size

AWG

26

24

22

20

18

16

15

14

13

12

11

10

B68585XX

B68584XX

B68583XX

B68582XX

B68581XX

B68580XX

B68579XX

B68578XX

B685A31XX

B68578XX

B685A39XX

B68577XX

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 260 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

Max.

Conductor

Resistance

0

at 20 C

(NPC)

Max.

Min.

145