Table of Contents Table of Contents
Previous Page  49 / 162 Next Page
Information
Show Menu
Previous Page 49 / 162 Next Page
Page Background

Application

Product Construction

Technical Data

Wires & Cables

Siechem

SXL RoHS

ü

Temperature Range :

0

0

- 40 C to +125 C (3000 Hours)

ü

Standard : SAE J1128

ü

Test Voltage : 1 kV

ü

S : Special Purpose.

ü

XL : Cross linked polyolefin .

Nominal

Cross-

Section

No. of

Strands

Diameter of

Single wire

max.

Conductor Construction

Conductor

Diameter

Nom.

Cable

Overall

Diameter

Weight

Approx.

Max.

Insulation

Wall Thickness

Nom.

AWG

nos.

mm

mtrs

kg/km

mm

Standard

Length*

Part

Number

Current

Carrying

Capacity

mm

mm

Amps

SXL

Features

2D View

ü

Wire harness of low-tension electric circuits for

automobiles.

ü

Used in motorcycles and other motor vehicles for

starting, charging, lighting, signal and instrument

panel circuits.

ü

Especially used for circuits requiring heat resistance.

ü

Flame retardant

ü

Highly resistant against acids, lyes, petrol

and diesel.

ü

Extra Flexible conductor with Electron beam cross

linked polyolefin special purpose insulation for

smaller diameter and lesser weight.

ü

Extra flexibility.

ü

Heat resistant.

ü

Insulation : Electron beam cross linked

polyolefin.

ü

Colour : As per customer order.

ü

Single core

Wires & Cables

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.

Red - 01 Yellow - 02

Blue - 03

Black - 04

Green - 05 Yellow-Green - 06 Grey - 07

Brown - 08

White - 09

Orange - 10

Violet - 11

Chocolate - 12

Tan - 13

Charcoal - 14

LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19

Purple - 20

Pink - 21

0

0

ü

Current Carrying capacity given is for the maximum conductor operating temperature of 125 C and ambient air temperature of 40 C.

ü

* Other length as per Customer order.

*

Max.

Conductor

Resistance

0

at 20 C

Ω/km

ü

Conductor : Soft-annealed electrolytic copper

E- Cu ETP1 according to ASTM B3 bare conductor

construction according to SAE J 1128

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

821

48

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

11

15

18

29

42

65

93

93

35.7

22.7

15.4

9.3

5.9

3.7

2.4

2.4

18

23

29

40

53

70

91

91

2.8

3.0

3.4

3.9

4.6

5.3

6.2

6.2

1000

1000

1000

500

500

500

500

500

7

16

19

19

19

19

49

19

0.31

0.26

0.29

0.36

0.45

0.57

0.45

0.71

0.93

1.21

1.45

1.80

2.25

2.85

3.55

3.55

0.74

0.76

0.81

0.89

0.94

1.04

1.09

1.09

OHSAS

18001

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949

82182XX

82181XX

82180XX

82179XX

82178XX

82177XX

C82176XX

82176XX

20

18

16

14

12

10

8

8