Table of Contents Table of Contents
Previous Page  139 / 162 Next Page
Information
Show Menu
Previous Page 139 / 162 Next Page
Page Background

ü

Conductor : Stranded Bare Copper Coverd

Steel Wire

ü

Insulation : Polypropylene (PP)

ü

Insulation Colour : Natural

ü

Braiding : Braid of Tinned Copper wire,

CUETPI according to EN13602

ü

Separator Tape : Polyester tape

ü

Outer Sheath : Polyvinylchloride (PVC)

ü

Sheath Color : Black (or) as per Customer order

Application

Product Construction

Technical Data

Wires & Cables

Siechem

RG 174 Co - Axial Cable

ü

Temperature : - 40°C to +105°C

ü

Standard : ES 96220-01

ü

Nom. Capacitance at 1 kHz : 106 pF/m

ü

Characteristic impedance : 50± 3Ω

ü

Bending Radius :

Single : 5 x Cable OD

Multiple : 10 x Cable OD

Nominal

Cross-

Section

Strands

Wire

(Nom.)

Conductor Construction

Nom.

Overall

Diameter

Approx.

Cable

Weight

Nominal

Insulation

Wall Thickness

Conductor

Diameter

(Max.)

Nos.

mm

mm

mm mm

kg/km

Part

Number

mm

mm

mm

RG 174

ü

Coaxial cable to be used as car antenna cable and

feeder cable.

ü

Automotive inner Wiring for communication and

Electronic Devices.

ü

Automotive TV/ Radio.

ü

Drop Wire, House wiring to indoor.

ü

Monitoring / Security camera.

ü

Ringing circuit connection between high frequency

apparatus.

Wires & Cables

Max.

Conductor

Resistance

at 20°C

Ω/km

0.14

Core

Diameter

Nom.

Braiding

Wire Dia

Nom.

Outer Sheath

Thickness

0.52

0.50

0.16

2.80 ± 0.10

317

1.52 ± 0.05 0.10

0.40

13

No. of

Core

1

7

2D View

Features

ü

Low loss.

ü

Characteristic Impedance is constant in high

frequency domain.

ü

We are superior in flexibility workability

after being lightweight.

ü

It is high cover, low loss type.

Siechem

RG 174 Co - Axial Cable

No. of

Strand

Siechem Wires & Cables Meet EU RoHS Directive

Lead

Free

Hg

Free

Cd

Free

6+

Cr

Free

PBB

Free

PBDE

Free

Catalogue

No

B603A

www.siechem.com

All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and

Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

0.05

0.1

0.4

0.8

0.9

1.0

1.5

1.9

2.0

2.1

2.4

2.5

3.0

5.6

6.0

20.9

30.2

66.2

99.9

107.2

114.3

146.9

170.4

176.1

181.6

197.9

203.2

228.8

347.7

364.5

Attenuation

(dB/100m)

Nom.

Freq.

(GHz)

AS

9100

ISO

45001

ISO

9001

ISO

14001

IATF

16949

B603A260004

Nos.

Sq.mm

138