More Category
Cables by Segment
Cables by Standard
IEC 60092-376
RFA-HF (I) Cable (IEC 60092-376)
- Fixed installations on ships
- (EMC) Minimizes radio interferences and electrical influences
- Conductor : Electrolytic, stranded, annealed copper wire.
IEC 60228 Class 2
- Insulation : Cross Linked Polyethylene
- Pair Screen : Plastic coated aluminium tape and a tinned
copper drain wire
- Bedding : Separator tape
- Armour : Drain wire tinned copper
Aluminium polyester tape, coverage 100%
- Outer Sheath : Cross Linked Polyolefin, Standard colour Grey, Other colours on request
- Temperature Range : -40°C to +120°C
- Rated Voltage (U°/U) : 150/250 V (300V)
- Standard : IEC 60092-376
- Flame retardant : IEC – 60332-1-2
- Halogen free : IEC 60754 series
- Smoke emission : IEC 61034 series
Part Number |
Number of Cores and mm2
Per Conductor |
Outer Diameter in
mm approx. |
Copper Index
Kg/Km |
Total Weight
Kg/Km approx. |
327 06 02 |
2 x 2 x 0.5 |
10.19 |
17.41 |
107 |
327 06 04 |
4 x 2 x 0.5 |
11.65 |
34.82 |
149 |
327 06 07 |
7 x 2 x 0.5 |
13.88 |
60.94 |
217 |
327 06 08 |
8 x 2 x 0.5 |
15.65 |
69.64 |
253 |
327 06 10 |
10 x 2 x 0.5 |
17.77 |
87.05 |
309 |
327 06 12 |
12 x 2 x 0.5 |
18.53 |
104.46 |
353 |
327 06 14 |
14 x 2 x 0.5 |
19.41 |
121.87 |
391 |
327 06 19 |
19 x 2 x 0.5 |
21.67 |
165.40 |
496 |
327 06 24 |
24 x 2 x 0.5 |
25.56 |
208.92 |
632 |