IEC 60092-353

LKEM-HF Cable

  • Fixed installations in Ships, Switchboards, Control panels and other enclosures

  • Conductor : Electrolytic, stranded, annealed copper wire.
    IEC 60228 Class 5
  • Insulation : Cross Linked Polyethylene

  • Temperature Range                       : -40°C to +120°C
  • Rated Voltage (U°/U)                     : 0.6/1k V (1.2kV)
  • Test Voltage                                    : 3.5 kV

  • Flame retardant : IEC – 60332-1-2
  • Halogen free : IEC 60754 series
  • Smoke emission : IEC 61034 series

Part Number Number of Cores and mm2
Per Conductor
Outer Diameter in
mm approx.
Copper Index
Kg/Km
Total Weight
Kg/Km approx.
318 08 XX* 1C x 0.75 2.74 6.40 14
318 10 XX 1C x 1.0 2.91 8.53 16
318 13 XX 1C x 1.5 3.19 12.80 22
318 16 XX 1C x 2.5 3.65 21.34 32
318 19 XX 1C x 4 4.2 34.14 47
318 23 XX 1C x 6 4.79 51.21 66
318 27 XX 1C x 10 5.72 85.34 104
318 28 XX 1C x 16 7.21 132.28 162
318 30 XX 1C x 25 9.1 206.69 254
318 32 XX 1C x 35 10.51 289.37 349
318 34 XX 1C x 50 12.63 413.39 501
318 37 XX 1C x 70 15 578.74 701
318 38 XX 1C x 95 17.04 785.43 939
318 41 XX 1C x 120 18.9 992.12 1172
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red-01 Yellow-02 Blue-03 Black-04 Green-05 Yellow-Green-06 Grey-07 Brown-08 White-09 Orange-10 Violet-11
Chocolate-12 Tan-13 Charcoal-14 LT Blue-15 DK Grey-16 LT Green-17 DK Green-18 DK Blue-19 Purple-20 Pink-21