- Manufacturing specifications STD 7611,131.
Part Number |
Conductor Construction | Insulation Wall Thickness Min. |
Cable | Max. Conductor Resistance at 200C |
Max. Conductor Resistance at 200C |
Standard Length* |
||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Nom |
Overall Diameter Max |
Weight Approx. |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
86605XX* | 0.35 | 7 | 0.26 | 0.78 | 0.20 | 1.4 | 4.5 | 54.4 | 5 | 500 |
86606XX | 0.5 | 19 | 0.19 | 0.95 | 0.22 | 1.6 | 6 | 37.1 | 8 | 500 |
86608XX | 0.75 | 19 | 0.23 | 0.95 | 0.24 | 1.9 | 9.4 | 24.7 | 10 | 500 |
86610XX | 1 | 32 | 0.20 | 1.50 | 0.24 | 2.1 | 12 | 18.5 | 12 | 500 |
86613XX | 1.5 | 37 | 0.22 | 1.54 | 0.24 | 2.4 | 16 | 12.7 | 16 | 500 |
86616XX | 2.5 | 37 | 0.28 | 1.54 | 0.28 | 3.0 | 25 | 7.6 | 22 | 500 |
86619XX | 4 | 56 | 0.31 | 2.80 | 0.32 | 3.7 | 42 | 4.71 | 30 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.